Your browser doesn't support javascript.
loading
Biomechanical analysis of practitioner's gesture for peripheral venous catheter insertion.
Torossian, K; Ottenio, M; Brulez, A-C; Lafon, Y; Viste, A; Attali, P; Benayoun, S.
Afiliación
  • Torossian K; Laboratoire de Tribologie et Dynamique des Systèmes, UMR CNRS 5513, Ecole Centrale de Lyon, 36 avenue Guy de Collongues, 69134 Ecully, France; Univ Lyon, Université Claude Bernard Lyon 1, Univ Gustave Eiffel, IFSTTAR, LBMC UMR_T9406, F69622 Lyon, France. Electronic address: kevin.torossian@gmail.com
  • Ottenio M; Univ Lyon, Université Claude Bernard Lyon 1, Univ Gustave Eiffel, IFSTTAR, LBMC UMR_T9406, F69622 Lyon, France.
  • Brulez AC; Laboratoire de Génie de la Fonctionnalisation des Matériaux Polymères, Institut Textile et Chimique de Lyon, 87 chemin des Mouilles, 69134 Ecully cedex, France.
  • Lafon Y; Univ Lyon, Université Claude Bernard Lyon 1, Univ Gustave Eiffel, IFSTTAR, LBMC UMR_T9406, F69622 Lyon, France.
  • Viste A; Univ Lyon, Université Claude Bernard Lyon 1, Univ Gustave Eiffel, IFSTTAR, LBMC UMR_T9406, F69622 Lyon, France; Hospices Civils de Lyon, Hôpital Lyon Sud, Chirurgie Orthopédique, 165 Chemin du Grand Revoyet, 69495 Pierre Benite Cedex, France.
  • Attali P; Institut de Formation en Soins Infirmiers, 5 Avenue Esquirol, 69003 Lyon, France.
  • Benayoun S; Laboratoire de Tribologie et Dynamique des Systèmes, UMR CNRS 5513, Ecole Centrale de Lyon, 36 avenue Guy de Collongues, 69134 Ecully, France.
Med Eng Phys ; 90: 92-99, 2021 04.
Article en En | MEDLINE | ID: mdl-33781485
ABSTRACT
Peripheral venous catheter insertion (PVCI) is one of the most common procedures performed by healthcare professionals but remains technically difficult. To develop new medical simulators with better representativeness of the human forearm, an experimental study was performed to collect data related to the puncturing of human skin and a vein in the antebrachial area. A total of 31 volunteers participated in this study. Force sensors and digital image correlation were used to measure the force during the palpation and puncturing of the vein and to retrieve the kinematics of the practitioner's gesture. The in vivo skin rupture load, vein rupture load, and friction loads for skin only and for both the skin and vein were (mean ± standard deviation) 0.85 ± 0.34 N, 1.25 ± 0.37 N, -0.49 ± 0.19 N, and -0.51 ± 0.16 N, respectively. The results of this study can be used to develop realistic skin and vein substitutes and mechanically assess them by reproducing the practitioner's gesture in a controlled fashion.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Cateterismo Periférico / Gestos Límite: Humans Idioma: En Revista: Med Eng Phys Asunto de la revista: BIOFISICA / ENGENHARIA BIOMEDICA Año: 2021 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Cateterismo Periférico / Gestos Límite: Humans Idioma: En Revista: Med Eng Phys Asunto de la revista: BIOFISICA / ENGENHARIA BIOMEDICA Año: 2021 Tipo del documento: Article