Influence of cleaning methods after 3D printing on two-body wear and fracture load of resin-based temporary crown and bridge material.
Mayer, Johannes; Stawarczyk, Bogna; Vogt, Konstantin; Hickel, Reinhard; Edelhoff, Daniel; Reymus, Marcel.
Afiliación
  • Mayer J; Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestrasse 70, 80336, Munich, Germany. Johannes.mayer@med.uni-muenchen.de.
  • Stawarczyk B; Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestrasse 70, 80336, Munich, Germany.
  • Vogt K; Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestrasse 70, 80336, Munich, Germany.
  • Hickel R; Department of Conservative Dentistry and Periodontology, University Hospital, LMU Munich, Goethestrasse 70, 80336, Munich, Germany.
  • Edelhoff D; Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestrasse 70, 80336, Munich, Germany.
  • Reymus M; Department of Conservative Dentistry and Periodontology, University Hospital, LMU Munich, Goethestrasse 70, 80336, Munich, Germany.
Clin Oral Investig ; 25(10): 5987-5996, 2021 Oct.
Article en En | MEDLINE | ID: mdl-33811531
ABSTRACT

OBJECTIVES:

To investigate the impact of different cleaning methods on the fracture load and two-body wear of additively manufactured three-unit fixed dental prostheses (FDP) for long-term temporary use, compared to the respective outcomes of milled provisional PMMA FDPs. MATERIALS AND

METHODS:

Shape congruent three-unit FDPs were 3D printed using three different resin-based materials [FPT, GCT, NMF] or milled [TEL] (N = 48, n = 16 per group). After printing, the FDPs were cleaned using Isopropanol (ISO), Yellow Magic 7 (YEL), or centrifugal force (CEN). Chewing simulation was carried out with a vertical load of 50 N (480,000 × 5 °C/55 °C). Two-body wear and fracture load were measured. Data were analyzed using global univariate ANOVA with partial eta squared, Kruskal-Wallis H, Mann-Whitney U, and Spearman's rho test (p < 0.05).

RESULTS:

TEL showed less wear resistance than FPT (p = 0.001) for all cleaning methods tested. Concerning vertical material loss, NMF and GCT were in the same range of value (p = 0.419-0.997), except within FDPs cleaned in ISO (p = 0.021). FPT showed no impact of cleaning method on wear resistance (p = 0.219-0.692). TEL (p < 0.001) showed the highest and FPT (p < 0.001) the lowest fracture load. Regarding the cleaning methods, specimens treated with ISO showed lower fracture load than specimens cleaned with CEN (p = 0.044) or YEL (p = 0.036).

CONCLUSIONS:

The material selection and the cleaning method can have an impact on two-body wear and fracture load results. CLINICAL RELEVANCE Printed restorations showed superior two-body wear resistance compared to milled FDPs but lower fracture load values. Regarding cleaning methods, ISO showed a negative effect on fracture load compared to the other methods tested.