Your browser doesn't support javascript.
loading
Rapid microscopic fractional anisotropy imaging via an optimized linear regression formulation.
Arezza, N J J; Tse, D H Y; Baron, C A.
Afiliación
  • Arezza NJJ; Centre for Functional and Metabolic Mapping (CFMM), Robarts Research Institute, University of Western Ontario, London, Canada; Department of Medical Biophysics, Schulich School of Medicine and Dentistry, University of Western Ontario, London, Canada. Electronic address: narezza@uwo.ca.
  • Tse DHY; Centre for Functional and Metabolic Mapping (CFMM), Robarts Research Institute, University of Western Ontario, London, Canada.
  • Baron CA; Centre for Functional and Metabolic Mapping (CFMM), Robarts Research Institute, University of Western Ontario, London, Canada; Department of Medical Biophysics, Schulich School of Medicine and Dentistry, University of Western Ontario, London, Canada.
Magn Reson Imaging ; 80: 132-143, 2021 07.
Article en En | MEDLINE | ID: mdl-33945859
Water diffusion anisotropy in the human brain is affected by disease, trauma, and development. Microscopic fractional anisotropy (µFA) is a diffusion MRI (dMRI) metric that can quantify water diffusion anisotropy independent of neuron fiber orientation dispersion. However, there are several different techniques to estimate µFA and few have demonstrated full brain imaging capabilities within clinically viable scan times and resolutions. Here, we present an optimized spherical tensor encoding (STE) technique to acquire µFA directly from the 2nd order cumulant expansion of the powder averaged dMRI signal obtained from direct linear regression (i.e. diffusion kurtosis) which requires fewer powder-averaged signals than other STE fitting techniques and can be rapidly computed. We found that the optimal dMRI parameters for white matter µFA imaging were a maximum b-value of 2000 s/mm2 and a ratio of STE to LTE tensor encoded acquisitions of 1.7 for our system specifications. We then compared two implementations of the direct regression approach to the well-established gamma model in 4 healthy volunteers on a 3 Tesla system. One implementation used mean diffusivity (D) obtained from a 2nd order fit of the cumulant expansion, while the other used a linear estimation of D from the low b-values. Both implementations of the direct regression approach showed strong linear correlations with the gamma model (ρ = 0.97 and ρ = 0.90) but mean biases of -0.11 and - 0.02 relative to the gamma model were also observed, respectively. All three µFA measurements showed good test-retest reliability (ρ ≥ 0.79 and bias = 0). To demonstrate the potential scan time advantage of the direct approach, 2 mm isotropic resolution µFA was demonstrated over a 10 cm slab using a subsampled data set with fewer powder-averaged signals that would correspond to a 3.3-min scan. Accordingly, our results introduce an optimization procedure that has enabled nearly full brain µFA in only several minutes.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Imagen de Difusión Tensora / Sustancia Blanca Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: Magn Reson Imaging Año: 2021 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Imagen de Difusión Tensora / Sustancia Blanca Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: Magn Reson Imaging Año: 2021 Tipo del documento: Article