Inter-laboratory comparison of gene expression biodosimetry for protracted radiation exposures as part of the RENEB and EURADOS WG10 2019 exercise.
Abend, M; Amundson, S A; Badie, C; Brzoska, K; Hargitai, R; Kriehuber, R; Schüle, S; Kis, E; Ghandhi, S A; Lumniczky, K; Morton, S R; O'Brien, G; Oskamp, D; Ostheim, P; Siebenwirth, C; Shuryak, I; Szatmári, T; Unverricht-Yeboah, M; Ainsbury, E; Bassinet, C; Kulka, U; Oestreicher, U; Ristic, Y; Trompier, F; Wojcik, A; Waldner, L; Port, M.
Afiliación
  • Abend M; Bundeswehr Institute of Radiobiology Affiliated to University Ulm, Neuherbergstr. 11, 80937, Munich, Germany. michaelabend@bundeswehr.org.
  • Amundson SA; Center for Radiological Research, Columbia University Irving Medical Center (CUIMC), New York, USA.
  • Badie C; Cancer Mechanisms and Biomarkers, Radiation Effects Dept, Centre for Radiation, Chemical and Environmental Hazards, Public Health England Chilton, Didcot, UK.
  • Brzoska K; Institute of Nuclear Chemistry and Technology, Centre for Radiobiology and Biological Dosimetry, Warsaw, Poland.
  • Hargitai R; Radiation Medicine Unit, National Public Health Center (NPHC), Budapest, Hungary.
  • Kriehuber R; Department of Safety and Radiation Protection, Forschungszentrum Jülich (FZJ), Jülich, Germany.
  • Schüle S; Bundeswehr Institute of Radiobiology Affiliated to University Ulm, Neuherbergstr. 11, 80937, Munich, Germany.
  • Kis E; Radiation Medicine Unit, National Public Health Center (NPHC), Budapest, Hungary.
  • Ghandhi SA; Center for Radiological Research, Columbia University Irving Medical Center (CUIMC), New York, USA.
  • Lumniczky K; Radiation Medicine Unit, National Public Health Center (NPHC), Budapest, Hungary.
  • Morton SR; Center for Radiological Research, Columbia University Irving Medical Center (CUIMC), New York, USA.
  • O'Brien G; Cancer Mechanisms and Biomarkers, Radiation Effects Dept, Centre for Radiation, Chemical and Environmental Hazards, Public Health England Chilton, Didcot, UK.
  • Oskamp D; Department of Safety and Radiation Protection, Forschungszentrum Jülich (FZJ), Jülich, Germany.
  • Ostheim P; Bundeswehr Institute of Radiobiology Affiliated to University Ulm, Neuherbergstr. 11, 80937, Munich, Germany.
  • Siebenwirth C; Bundeswehr Institute of Radiobiology Affiliated to University Ulm, Neuherbergstr. 11, 80937, Munich, Germany.
  • Shuryak I; Center for Radiological Research, Columbia University Irving Medical Center (CUIMC), New York, USA.
  • Szatmári T; Radiation Medicine Unit, National Public Health Center (NPHC), Budapest, Hungary.
  • Unverricht-Yeboah M; Department of Safety and Radiation Protection, Forschungszentrum Jülich (FZJ), Jülich, Germany.
  • Ainsbury E; Centre for Radiation, Chemical and Environmental Hazards, Public Health England Chilton, Didcot, UK.
  • Bassinet C; Institute of Radiation Protection and Nuclear Safety, PSE-SANTE/SDOS/LDRI, 92262, Fontenay-aux-Roses, France.
  • Kulka U; Bundesamt für Strahlenschutz (BfS), Federal Office for Radiation Protection, Oberschleissheim, Germany.
  • Oestreicher U; Bundesamt für Strahlenschutz (BfS), Federal Office for Radiation Protection, Oberschleissheim, Germany.
  • Ristic Y; Institute of Radiation Protection and Nuclear Safety, PSE-SANTE/SDOS/LDRI, 92262, Fontenay-aux-Roses, France.
  • Trompier F; Institute of Radiation Protection and Nuclear Safety, PSE-SANTE/SDOS/LDRI, 92262, Fontenay-aux-Roses, France.
  • Wojcik A; Centre for Radiation Protection Research, Department of Molecular Biosciences, The Wenner-Gren Institute, Stockholm University, Stockholm, Sweden.
  • Waldner L; Department of Translational Medicine, Medical Radiation Physics, Lund University, Malmö, Sweden.
  • Port M; Bundeswehr Institute of Radiobiology Affiliated to University Ulm, Neuherbergstr. 11, 80937, Munich, Germany.
Sci Rep ; 11(1): 9756, 2021 05 07.
Article en En | MEDLINE | ID: mdl-33963206
ABSTRACT
Large-scale radiation emergency scenarios involving protracted low dose rate radiation exposure (e.g. a hidden radioactive source in a train) necessitate the development of high throughput methods for providing rapid individual dose estimates. During the RENEB (Running the European Network of Biodosimetry) 2019 exercise, four EDTA-blood samples were exposed to an Iridium-192 source (1.36 TBq, Tech-Ops 880 Sentinal) at varying distances and geometries. This resulted in protracted doses ranging between 0.2 and 2.4 Gy using dose rates of 1.5-40 mGy/min and exposure times of 1 or 2.5 h. Blood samples were exposed in thermo bottles that maintained temperatures between 39 and 27.7 °C. After exposure, EDTA-blood samples were transferred into PAXGene tubes to preserve RNA. RNA was isolated in one laboratory and aliquots of four blinded RNA were sent to another five teams for dose estimation based on gene expression changes. Using an X-ray machine, samples for two calibration curves (first constant dose rate of 8.3 mGy/min and 0.5-8 h varying exposure times; second varying dose rates of 0.5-8.3 mGy/min and 4 h exposure time) were generated for distribution. Assays were run in each laboratory according to locally established protocols using either a microarray platform (one team) or quantitative real-time PCR (qRT-PCR, five teams). The qRT-PCR measurements were highly reproducible with coefficient of variation below 15% in ≥ 75% of measurements resulting in reported dose estimates ranging between 0 and 0.5 Gy in all samples and in all laboratories. Up to twofold reductions in RNA copy numbers per degree Celsius relative to 37 °C were observed. However, when irradiating independent samples equivalent to the blinded samples but increasing the combined exposure and incubation time to 4 h at 37 °C, expected gene expression changes corresponding to the absorbed doses were observed. Clearly, time and an optimal temperature of 37 °C must be allowed for the biological response to manifest as gene expression changes prior to running the gene expression assay. In conclusion, dose reconstructions based on gene expression measurements are highly reproducible across different techniques, protocols and laboratories. Even a radiation dose of 0.25 Gy protracted over 4 h (1 mGy/min) can be identified. These results demonstrate the importance of the incubation conditions and time span between radiation exposure and measurements of gene expression changes when using this method in a field exercise or real emergency situation.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Dosis de Radiación / Rayos X / Células Sanguíneas / Regulación de la Expresión Génica / Exposición a la Radiación / Rayos gamma / Laboratorios Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: Sci Rep Año: 2021 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Dosis de Radiación / Rayos X / Células Sanguíneas / Regulación de la Expresión Génica / Exposición a la Radiación / Rayos gamma / Laboratorios Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: Sci Rep Año: 2021 Tipo del documento: Article País de afiliación: Alemania