3D ultrasound imaging provides reliable angle measurement with validity comparable to X-ray in patients with adolescent idiopathic scoliosis.
J Orthop Translat
; 29: 51-59, 2021 Jul.
Article
en En
| MEDLINE
| ID: mdl-34094858
BACKGROUND & OBJECTIVE: The application of ultrasound imaging for spine evaluation could minimize radiation exposure for patients with adolescence idiopathic scoliosis (AIS). A customized three-dimensional (3D) ultrasound imaging system has been demonstrated to provide reliable and valid coronal curvature measurements. However, these measurements were using the spinous processes as anatomical reference, leading to a predictable underestimation of the traditionally used Cobb angles. An alternative 3D ultrasound image reconstruction method was applied to create coronal images with more lateral features for angle measurement. The objective of this study was to test the reliability and the validity of this angle, the ultrasound curve angle (UCA), and compare the UCA with the Cobb angles on X-ray images of patients with AIS. MATERIALS AND METHODS: This study was divided into: 1) Investigation of intra- and inter-reliability between two raters for measuring the UCA and two operators for acquiring ultrasound images; 2) Investigation of the validity between the radiographic Cobb angle and the UCA. Fifty patients and 164 patients with AIS, were included in the two stages, respectively. Patients underwent bi-planar X-ray and 3D ultrasound scanning on the same day. The proposed UCA was used to measure the coronal curvature from the ultrasound coronal images, which were formed using a newly customized volume projection imaging (VPI) method. The intra-rater/operator and inter-rater and operator reliability of the UCA were tested by intra-class correlation coefficient (ICC) (3,1) and (2,1), respectively. The validity of UCA measurements as compared to radiographic Cobb angles was tested by inter-method ICC (2,1), mean absolute difference (MAD), standard error of measurement (SEM), Pearson correlation coefficient and Bland-Altman statistics. The level of significance was set as 0.05. RESULTS: Excellent intra-rater and intra-operator (ICC (3,1)≥0.973) and excellent inter-rater and inter-operator reliability (ICC (2,1)≥0.925) for UCA measurement, with overall MAD and SEM no more than 3.5° and 1.7° were demonstrated for both main thoracic and (thoraco)lumbar curvatures. Very good correlations were observed between UCA and Cobb angle for main thoracic ( R 2 =0.893) and (thoraco)lumbar ( R 2 =0.884) curves. The mean (SD) measurements in terms of radiographic Cobb and UCA were 27.2 â± â11.6° and 26.3 â± â11.4° for main thoracic curves; and 26.2 â± â11.4° and 24.8 â± â9.7° for (thoraco)lumbar curve respectively. One hundred sixty-four subjects (33 male and 131 female subjects; 11-18 years of age, mean of 15.1 â± â1.9 years) were included for the validity session. Excellent inter-method variations (ICC (2,K) ≥0.933) with overall MAD and SEM no more than 3.0° and 1.5° were demonstrated for both main thoracic and (thoraco)lumbar curvatures. In addition, Bland-Altman plots demonstrated an acceptable agreement between ultrasound and radiographic Cobb measurements. CONCLUSION: In this study, very good correlations and agreement were demonstrated between the ultrasound and X-ray measurements of the scoliotic curvature. Judging from the promising results of this study, patients with AIS with different severity of curves can be evaluated and monitored by ultrasound imaging, reducing the usage of radiation during follow-ups. This method could also be used for scoliosis screening.The Translational potential of this article: Ultrasound curve angle (UCA) obtained from 3D ultrasound imaging system can provide reliable and valid evaluation on coronal curvature for patients with AIS, without the need of radiation.
Texto completo:
1
Colección:
01-internacional
Banco de datos:
MEDLINE
Idioma:
En
Revista:
J Orthop Translat
Año:
2021
Tipo del documento:
Article
País de afiliación:
Hong Kong