Your browser doesn't support javascript.
loading
Donnan Dialysis for scaling mitigation during electrochemical ammonium recovery from complex wastewater.
Rodrigues, Mariana; Paradkar, Aishwarya; Sleutels, Tom; Heijne, Annemiek Ter; Buisman, Cees J N; Hamelers, Hubertus V M; Kuntke, Philipp.
Afiliación
  • Rodrigues M; Wetsus, European Centre of Excellence for Sustainable Water Technology, Oostergoweg 9 8911MA Leeuwarden P.O. Box 1113, 8900 CC Leeuwarden, the Netherlands; Environmental Technology, Wageningen University, Bornse Weilanden 9 6708 WG Wageningen P.O. Box 17, 6700 AA Wageningen, the Netherlands.
  • Paradkar A; Wetsus, European Centre of Excellence for Sustainable Water Technology, Oostergoweg 9 8911MA Leeuwarden P.O. Box 1113, 8900 CC Leeuwarden, the Netherlands.
  • Sleutels T; Wetsus, European Centre of Excellence for Sustainable Water Technology, Oostergoweg 9 8911MA Leeuwarden P.O. Box 1113, 8900 CC Leeuwarden, the Netherlands.
  • Heijne AT; Environmental Technology, Wageningen University, Bornse Weilanden 9 6708 WG Wageningen P.O. Box 17, 6700 AA Wageningen, the Netherlands.
  • Buisman CJN; Wetsus, European Centre of Excellence for Sustainable Water Technology, Oostergoweg 9 8911MA Leeuwarden P.O. Box 1113, 8900 CC Leeuwarden, the Netherlands; Environmental Technology, Wageningen University, Bornse Weilanden 9 6708 WG Wageningen P.O. Box 17, 6700 AA Wageningen, the Netherlands.
  • Hamelers HVM; Wetsus, European Centre of Excellence for Sustainable Water Technology, Oostergoweg 9 8911MA Leeuwarden P.O. Box 1113, 8900 CC Leeuwarden, the Netherlands; Environmental Technology, Wageningen University, Bornse Weilanden 9 6708 WG Wageningen P.O. Box 17, 6700 AA Wageningen, the Netherlands.
  • Kuntke P; Wetsus, European Centre of Excellence for Sustainable Water Technology, Oostergoweg 9 8911MA Leeuwarden P.O. Box 1113, 8900 CC Leeuwarden, the Netherlands; Environmental Technology, Wageningen University, Bornse Weilanden 9 6708 WG Wageningen P.O. Box 17, 6700 AA Wageningen, the Netherlands. Electro
Water Res ; 201: 117260, 2021 Aug 01.
Article en En | MEDLINE | ID: mdl-34107362
ABSTRACT
Inorganic scaling is often an obstacle for implementing electrodialysis systems in general and for nutrient recovery from wastewater specifically. In this work, Donnan dialysis was explored, to prevent scaling and to prolong operation of an electrochemical system for TAN (total ammonia nitrogen) recovery. An electrochemical system was operated with and without an additional Donnan dialysis cell, while being supplied with synthetic influent and real digested black water. For the same Load Ratio (nitrogen load vs applied current) while treating digested black water, the system operated for a period three times longer when combined with a Donnan cell. Furthermore, the amount of nitrogen recovered was higher. System performance was evaluated in terms of both TAN recovery and energy efficiency, at different Load Ratios. At a Load Ratio 1.3 and current density of 10 A m-2, a TAN recovery of 83% was achieved while consuming 9.7 kWh kgN-1.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Aguas Residuales / Compuestos de Amonio Idioma: En Revista: Water Res Año: 2021 Tipo del documento: Article País de afiliación: Países Bajos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Aguas Residuales / Compuestos de Amonio Idioma: En Revista: Water Res Año: 2021 Tipo del documento: Article País de afiliación: Países Bajos