Your browser doesn't support javascript.
loading
Mobile intraoperative CT-assisted frameless stereotactic biopsies achieved single-millimeter trajectory accuracy for deep-seated brain lesions in a sample of 7 patients.
Bichsel, Oliver; Oertel, Markus F; Stieglitz, Lennart H.
Afiliación
  • Bichsel O; Department of Neurosurgery, University Hospital Zurich, University of Zurich, Zurich, Switzerland. oliver.bichsel@usz.ch.
  • Oertel MF; Clinical Neuroscience Center, University Hospital Zurich, University of Zurich, Zurich, Switzerland. oliver.bichsel@usz.ch.
  • Stieglitz LH; Department of Neurosurgery, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
BMC Neurol ; 21(1): 285, 2021 Jul 22.
Article en En | MEDLINE | ID: mdl-34294075
BACKGROUND: Brain biopsies are crucial diagnostic interventions, providing valuable information for treatment and prognosis, but largely depend on a high accuracy and precision. We hypothesized that through the combination of neuronavigation-based frameless stereotaxy and MRI-guided trajectory planning with intraoperative CT examination using a mobile unit, one can achieve a seamlessly integrated approach yielding optimal target accuracy. METHODS: We analyzed a total of 7 stereotactic biopsy trajectories for a variety of deep-seated locations and different patient positions. After rigid head fixation, an intraoperative pre-procedural scan using a mobile CT unit was performed for automatic image fusion with the planning MRI images and a peri-procedural scan with the biopsy cannula in situ for verification of the definite target position. We then evaluated the radial trajectory error. RESULTS: Intraoperative scanning, surgery, computerized merging of MRI and CT images as well as trajectory planning were feasible without difficulties and safe in all cases. We achieved a radial trajectory deviation of 0.97 ± 0.39 mm at a trajectory length of 60 ± 12.3 mm (mean ± standard deviation). Repositioning of the biopsy cannula due to inaccurate targeting was not required. CONCLUSION: Intraoperative verification using a mobile CT unit in combination with frameless neuronavigation-guided stereotaxy and pre-operative MRI-based trajectory planning was feasible, safe and highly accurate. The setting enabled single-millimeter accuracy for deep-seated brain lesions and direct detection of intraoperative complications, did not depend on a dedicated operating room and was seamlessly integrated into common stereotactic procedures.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Neoplasias Encefálicas / Tomografía Computarizada por Rayos X / Neuronavegación Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: BMC Neurol Asunto de la revista: NEUROLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Suiza

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Neoplasias Encefálicas / Tomografía Computarizada por Rayos X / Neuronavegación Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: BMC Neurol Asunto de la revista: NEUROLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Suiza