Hybrid versus total sublaminar wires in patients with spinal muscular atrophy undergoing scoliosis surgery.
BMC Musculoskelet Disord
; 22(1): 867, 2021 Oct 11.
Article
en En
| MEDLINE
| ID: mdl-34635092
BACKGROUND: Early versions of spinal muscular atrophy (SMA) scoliosis correction surgery often involved sublaminar devices. Recently, the utilization of pedicle screws has gained much popularity. Pedicle screws are generally believed to provide additional deformity correction, but pedicle size and rotational deformity limit their application in the thoracic spine, resulting in a hybrid construct involving pedicle screws and sublaminar wire. Studies of the efficacy of hybrid instrumentation in SMA scoliosis are often limited by the scarcity of the disease itself. In this study, we aimed to compare the surgical outcomes between hybrid constructs involving pedicle screws and sublaminar wire and sublaminar wire alone in patients with SMA scoliosis. METHODS: We retrospectively reviewed the clinical records and radiographic assessments of patients with SMA scoliosis who underwent corrective surgery between 1993 and 2017. The radiographic assessments included deformity correction and progressive changes in the major curve angle, pelvic tilt (PT) and coronal balance (CB). The correction of deformities was observed postoperatively and at the patient's 2-year follow-up to test the efficacy of each type of construct. RESULTS: Thirty-three patients were included in this study. There were 14 and 19 patients in the wiring and hybrid construct groups, respectively. The hybrid construct group demonstrated a higher major curve angle correction (50.5° ± 11.2° vs. 36.4° ± 8.4°, p < 0.001), a higher apical vertebral rotation correction (10.6° ± 3.9° vs. 4.8° ± 2.6°, p < 0.001), and a reduced progression of the major curve angle at the 2-year follow-up (5.1° ± 2.9° vs. 8.7° ± 4.8°, p < 0.001). A moderate correlation was observed between the magnitude of correction of the apical vertebral rotation angle and the major curve (r = 0.528, p = 0.002). CONCLUSION: This study demonstrated that hybrid instrumentation can provide a greater magnitude of correction in major curve and apical rotation as well as less major curve progression than sublaminar wire instrumentation alone in patients with SMA scoliosis. Level of evidence III.
Palabras clave
Texto completo:
1
Colección:
01-internacional
Banco de datos:
MEDLINE
Asunto principal:
Escoliosis
/
Atrofia Muscular Espinal
Tipo de estudio:
Observational_studies
Límite:
Humans
Idioma:
En
Revista:
BMC Musculoskelet Disord
Asunto de la revista:
FISIOLOGIA
/
ORTOPEDIA
Año:
2021
Tipo del documento:
Article
País de afiliación:
Taiwán