Your browser doesn't support javascript.
loading
Reagentless Acid-Base Titration for Alkalinity Detection in Seawater.
Wiorek, Alexander; Hussain, Ghulam; Molina-Osorio, Andres F; Cuartero, Maria; Crespo, Gaston A.
Afiliación
  • Wiorek A; Department of Chemistry, School of Engineering Science in Chemistry, Biochemistry and Health, KTH Royal Institute of Technology, SE-100 44 Stockholm, Sweden.
  • Hussain G; Department of Chemistry, School of Engineering Science in Chemistry, Biochemistry and Health, KTH Royal Institute of Technology, SE-100 44 Stockholm, Sweden.
  • Molina-Osorio AF; Department of Chemistry, School of Engineering Science in Chemistry, Biochemistry and Health, KTH Royal Institute of Technology, SE-100 44 Stockholm, Sweden.
  • Cuartero M; Department of Chemistry, School of Engineering Science in Chemistry, Biochemistry and Health, KTH Royal Institute of Technology, SE-100 44 Stockholm, Sweden.
  • Crespo GA; Department of Chemistry, School of Engineering Science in Chemistry, Biochemistry and Health, KTH Royal Institute of Technology, SE-100 44 Stockholm, Sweden.
Anal Chem ; 93(42): 14130-14137, 2021 10 26.
Article en En | MEDLINE | ID: mdl-34652903
ABSTRACT
Herein, we report on a reagentless electroanalytical methodology for automatized acid-base titrations of water samples that are confined into very thin spatial domains. The concept is based on the recent discovery from our group (Wiorek, A. Anal. Chem. 2019, 91, 14951-14959), in which polyaniline (PANI) films were found to be an excellent material to release a massive charge of protons in a short time, achieving hence the efficient (and controlled) acidification of a sample. We now demonstrate and validate the analytical usefulness of this approach with samples collected from the Baltic Sea the titration protocol indeed acts as an alkalinity sensor via the calculation of the proton charge needed to reach pH 4.0 in the sample, as per the formal definition of the alkalinity parameter. In essence, the alkalinity sensor is based on the linear relationship found between the released charge from the PANI film and the bicarbonate concentration in the sample (i.e., the way to express alkalinity measurements). The observed alkalinity in the samples presented a good agreement with the values obtained by manual (classical) acid-base titrations (discrepancies <10%). Some crucial advantages of the new methodology are that titrations are completed in less than 1 min (end point), the PANI film can be reused at least 74 times over a 2 week period (<5% of decrease in the released charge), and the utility of the PANI film to even more decrease the final pH of the sample (pH ∼2) toward applications different from alkalinity detection. Furthermore, the acidification can be accomplished in a discrete or continuous mode depending on the application demands. The new methodology is expected to impact the future digitalization of in situ acid-base titrations to obtain high-resolution data on alkalinity in water resources.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Agua de Mar / Bicarbonatos Tipo de estudio: Diagnostic_studies Idioma: En Revista: Anal Chem Año: 2021 Tipo del documento: Article País de afiliación: Suecia

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Agua de Mar / Bicarbonatos Tipo de estudio: Diagnostic_studies Idioma: En Revista: Anal Chem Año: 2021 Tipo del documento: Article País de afiliación: Suecia