Your browser doesn't support javascript.
loading
An electrochemical aptasensor for Mycobacterium tuberculosis ESAT-6 antigen detection using bimetallic organic framework.
Xie, Jiaojiao; Mu, Zhaode; Yan, Bin; Wang, Jie; Zhou, Jing; Bai, Lijuan.
Afiliación
  • Xie J; Chongqing Research Center for Pharmaceutical Engineering, College of Pharmacy, Chongqing Medical University, Chongqing, 400016, People's Republic of China.
  • Mu Z; Research Center for Pharmacodynamic Evaluation Engineering Technology of Chongqing, College of Pharmacy, Chongqing Medical University, Chongqing, 400016, People's Republic of China.
  • Yan B; The Eighth Middle School of Chongqing, Chongqing, 400030, People's Republic of China.
  • Wang J; Research Center for Pharmacodynamic Evaluation Engineering Technology of Chongqing, College of Pharmacy, Chongqing Medical University, Chongqing, 400016, People's Republic of China.
  • Zhou J; Chongqing Research Center for Pharmaceutical Engineering, College of Pharmacy, Chongqing Medical University, Chongqing, 400016, People's Republic of China.
  • Bai L; Chongqing Research Center for Pharmaceutical Engineering, College of Pharmacy, Chongqing Medical University, Chongqing, 400016, People's Republic of China. bailijua88@126.com.
Mikrochim Acta ; 188(11): 404, 2021 Nov 03.
Article en En | MEDLINE | ID: mdl-34731314
ABSTRACT
A label-free electrochemical aptasensor is reported for sensitive detection of the 6-kDa early secreted antigenic target (ESAT-6). For the first time, the bimetallic organic framework (b-MOF) of Zr-MOF-on-Ce-MOF was decorated with nitrogen-doped graphene (NG) and applied as the matrix for electroactive toluidine blue (Tb) to form the NG@Zr-MOF-on-Ce-MOF@Tb nanohybrid. The prepared nanohybrid with excellent hydrophilicity, dispersibility, and large specific surface exhibited significant electrochemical response. This nanohybrid could be directly used for anchoring ESAT-6 binding aptamers (EBA) through the interaction between the 5'-phosphate group (PO43-) of EBA and Zr4+ of Zr-MOF. The signal response before and after incubating the ESAT-6 antigen has been evaluated by cyclic voltammetry at a scan rate of 100 mV s-1 from - 0.7 to 0.3 V (vs. SCE). Under optimal conditions, the proposed aptasensor displayed a wide linear range from 100 fg mL-1 to 10 ng mL-1 with a limit of detection (LOD) of 12 fg mL-1. The developed method showed good reproducibility with a relative standard deviation (RSD) of 2.27%. The aptasensor showed favorable results in the analysis of the real samples. With these merits, the aptasensor has exceptional potential as a diagnostic tool for tuberculosis in clinical practice.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Proteínas Bacterianas / Técnicas Biosensibles / Aptámeros de Nucleótidos / Estructuras Metalorgánicas / Mycobacterium tuberculosis / Antígenos Bacterianos Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Mikrochim Acta Año: 2021 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Proteínas Bacterianas / Técnicas Biosensibles / Aptámeros de Nucleótidos / Estructuras Metalorgánicas / Mycobacterium tuberculosis / Antígenos Bacterianos Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Mikrochim Acta Año: 2021 Tipo del documento: Article