Your browser doesn't support javascript.
loading
Dual energy X-ray beam ptycho-fluorescence imaging.
Cipiccia, Silvia; Brun, Francesco; Di Trapani, Vittorio; Rau, Christoph; Batey, Darren J.
Afiliación
  • Cipiccia S; Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London WC1E 6BT, United Kingdom.
  • Brun F; Department of Engineering and Architecture, University of Trieste, Via Alfonso Valerio 6/1, Trieste 34127, Italy.
  • Di Trapani V; Department of Physics, University of Trieste, Via Alfonso Valerio 6/1, Trieste 34127, Italy.
  • Rau C; Diamond Light Source, Harwell Science and Innovation Campus, Fermi Avenue, Didcot OX11 0QX, United Kingdom.
  • Batey DJ; Diamond Light Source, Harwell Science and Innovation Campus, Fermi Avenue, Didcot OX11 0QX, United Kingdom.
J Synchrotron Radiat ; 28(Pt 6): 1916-1920, 2021 Nov 01.
Article en En | MEDLINE | ID: mdl-34738946
ABSTRACT
X-ray ptychography and X-ray fluorescence are complementary nanoscale imaging techniques, providing structural and elemental information, respectively. Both methods acquire data by scanning a localized beam across the sample. X-ray ptychography processes the transmission signal of a coherent illumination interacting with the sample, to produce images with a resolution finer than the illumination spot and step size. By enlarging both the spot and the step size, the technique can cover extended regions efficiently. X-ray fluorescence records the emitted spectra as the sample is scanned through the localized beam and its spatial resolution is limited by the spot and step size. The requisites for fast ptychography and high-resolution fluorescence appear incompatible. Here, a novel scheme that mitigates the difference in requirements is proposed. The method makes use of two probes of different sizes at the sample, generated by using two different energies for the probes and chromatic focusing optics. The different probe sizes allow to reduce the number of acquisition steps for the joint fluorescence-ptychography scan compared with a standard single beam scan, while imaging the same field of view. The new method is demonstrated experimentally using two undulator harmonics, a Fresnel zone plate and an energy discriminating photon counting detector.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Fotones / Imagen Óptica Tipo de estudio: Diagnostic_studies Idioma: En Revista: J Synchrotron Radiat Asunto de la revista: RADIOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Reino Unido

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Fotones / Imagen Óptica Tipo de estudio: Diagnostic_studies Idioma: En Revista: J Synchrotron Radiat Asunto de la revista: RADIOLOGIA Año: 2021 Tipo del documento: Article País de afiliación: Reino Unido