Your browser doesn't support javascript.
loading
Identifying the contribution of charge effects to airborne transmission of aerosols in confined spaces.
Wang, Wenlu; Kimoto, Shigeru; Huang, Riping; Matsui, Yasuto; Yoneda, Minoru; Wang, Hao; Wang, Boguang.
Afiliación
  • Wang W; Institute for Environmental and Climate Research, Jinan University, Guangzhou 511443, China; Department of Environmental Engineering, Graduate School of Engineering, Kyoto University, Kyoto 615-8540, Japan. Electronic address: wenluwang@jnu.edu.cn.
  • Kimoto S; Department of Environmental Engineering, Graduate School of Engineering, Kyoto University, Kyoto 615-8540, Japan.
  • Huang R; Department of Environmental Engineering, Graduate School of Engineering, Kyoto University, Kyoto 615-8540, Japan.
  • Matsui Y; Department of Environmental Engineering, Graduate School of Engineering, Kyoto University, Kyoto 615-8540, Japan.
  • Yoneda M; Department of Environmental Engineering, Graduate School of Engineering, Kyoto University, Kyoto 615-8540, Japan.
  • Wang H; Institute for Environmental and Climate Research, Jinan University, Guangzhou 511443, China; Australia-China Centre for Air Quality Science and Management (Guangdong), Jinan University, Guangzhou 511443, China.
  • Wang B; Institute for Environmental and Climate Research, Jinan University, Guangzhou 511443, China; Australia-China Centre for Air Quality Science and Management (Guangdong), Jinan University, Guangzhou 511443, China.
Sci Total Environ ; 816: 151527, 2022 Apr 10.
Article en En | MEDLINE | ID: mdl-34762944
Aerosols in indoor air have various adverse effects on human health. Considering the use of forced ventilation and fan mixing (individually and in combination), the variation in charge number and their effects on aerosol transmission in confined spaces were explored in this study with the distinction of particle sources. In the case of sources originating from the external space, natural penetration acquires a greater number of negative charges. Forced ventilation of a confined space acts on the fate of particles in the neighboring confined space, while the internal fan has a negligible effect on both the number concentration and charge number of particles in the exterior. The combination of forced ventilation and fan mixing increases charge numbers, altering the lifetime of particles in the external regional environment by deposition or adsorption, particularly for neutralized particles. In the case of sources originating from the interior area, application of an internal fan weakens the ventilation effect from forced ventilation, resulting in internal particle loss by depositing on internal surfaces due to electrostatic charge, increasing the potential risk of resuspension. Additionally, source origin is associated with particle fate, and the charge generated under the action of external forces contributes to the transmission pathways and the fate of the particles in the air. This study investigates the transmission pathways and the fate of aerosols from the perspective of charge number, hopefully contributing to an in-depth understanding of the transmission mechanisms of toxic substances in confined spaces with aerosols as carriers.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Contaminación del Aire Interior / Espacios Confinados Límite: Humans Idioma: En Revista: Sci Total Environ Año: 2022 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Contaminación del Aire Interior / Espacios Confinados Límite: Humans Idioma: En Revista: Sci Total Environ Año: 2022 Tipo del documento: Article