Your browser doesn't support javascript.
loading
Does mechanical dyssynchrony in addition to QRS area ensure sustained response to cardiac resynchronization therapy?
Wouters, Philippe C; van Everdingen, Wouter M; Vernooy, Kevin; Geelhoed, Bastiaan; Allaart, Cornelis P; Rienstra, Michiel; Maass, Alexander H; Vos, Marc A; Prinzen, Frits W; Meine, Mathias; Cramer, Maarten J.
Afiliación
  • Wouters PC; Department of Cardiology, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands.
  • van Everdingen WM; Department of Cardiology, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands.
  • Vernooy K; Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Centre+ (MUMC+), 6229 HX Maastricht, The Netherlands.
  • Geelhoed B; Department of Cardiology, Radboud University Medical Center, 6525 GA Nijmegen, The Netherlands.
  • Allaart CP; Department of Cardiology, Thoraxcentre, University of Groningen, University Medical Center Groningen, 9713 GZ Groningen, The Netherlands.
  • Rienstra M; Department of Cardiology, Amsterdam University Medical Center, Location VU University Medical Center, 1081 HV Amsterdam, The Netherlands.
  • Maass AH; Department of Cardiology, Thoraxcentre, University of Groningen, University Medical Center Groningen, 9713 GZ Groningen, The Netherlands.
  • Vos MA; Department of Cardiology, Thoraxcentre, University of Groningen, University Medical Center Groningen, 9713 GZ Groningen, The Netherlands.
  • Prinzen FW; Department of Medical Physiology, University of Utrecht, 3584 CM Utrecht, The Netherlands.
  • Meine M; Department of Physiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, 6229 ER Masstricht, The Netherlands.
  • Cramer MJ; Department of Cardiology, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands.
Eur Heart J Cardiovasc Imaging ; 23(12): 1628-1635, 2022 11 17.
Article en En | MEDLINE | ID: mdl-34871385
AIMS: Judicious patient selection for cardiac resynchronization therapy (CRT) may further enhance treatment response. Progress has been made by using improved markers of electrical dyssynchrony and mechanical discoordination, using QRSAREA, and systolic rebound stretch of the septum (SRSsept) or systolic stretch index (SSI), respectively. To date, the relation between these measurements has not yet been investigated. METHODS AND RESULTS: A total of 240 CRT patients were prospectively enrolled from six centres. Patients underwent standard 12-lead electrocardiography, and echocardiography, at baseline, 6-month, and 12-month follow-up. QRSAREA was derived using vectorcardiography, and SRSsept and SSI were measured using strain-analysis. Reverse remodelling was measured as the relative decrease in left ventricular end-systolic volume, indexed to body surface area (ΔLVESVi). Sustained response was defined as ≥15% decrease in LVESVi, at both 6- and 12-month follow-up. QRSAREA and SRSsept were both strong, multivariable adjusted, variables associated with reverse remodelling. SRSsept was associated with response, but only in patients with QRSAREA ≥ 120 µVs (AUC = 0.727 vs. 0.443). Combined presence of SRSsept ≥ 2.5% and QRSAREA ≥ 120 µVs significantly increased reverse remodelling compared with high QRSAREA alone (ΔLVESVi 38 ± 21% vs. 22 ± 21%). As a result, 92% of left bundle branch block (LBBB)-patients with combined electrical and mechanical dysfunction were 'sustained' volumetric responders, as opposed to 51% with high QRSAREA alone. CONCLUSION: Parameters of mechanical dyssynchrony are better associated with response in the presence of a clear underlying electrical substrate. Combined presence of high SRSsept and QRSAREA, but not high QRSAREA alone, ensures a sustained response after CRT in LBBB patients.