Your browser doesn't support javascript.
loading
Assessment Parameters for Arrayed Pulse Wave Analysis and Application in Hypertensive Disorders.
Bi, Zi-Juan; Yao, Xing-Hua; Hu, Xiao-Juan; Yuan, Pei; Guo, Xiao-Jing; Guo, Zhi-Ling; Wang, Si-Han; Li, Jun; Shi, Yu-Lin; Li, Jia-Cai; Cui, Ji; Xu, Jia-Tuo.
Afiliación
  • Bi ZJ; Basic Medicine College, Shanghai University of Traditional Chinese Medicine, 1200 Cailun Road, Shanghai 201203, China.
  • Yao XH; Basic Medicine College, Shanghai University of Traditional Chinese Medicine, 1200 Cailun Road, Shanghai 201203, China.
  • Hu XJ; Shanghai Innovation Center of TCM Health Service, Shanghai University of Traditional Chinese Medicine, 1200 Cailun Road, Shanghai 201203, China.
  • Yuan P; Basic Medicine College, Shanghai University of Traditional Chinese Medicine, 1200 Cailun Road, Shanghai 201203, China.
  • Guo XJ; Basic Medicine College, Shanghai University of Traditional Chinese Medicine, 1200 Cailun Road, Shanghai 201203, China.
  • Guo ZL; Basic Medicine College, Shanghai University of Traditional Chinese Medicine, 1200 Cailun Road, Shanghai 201203, China.
  • Wang SH; Basic Medicine College, Shanghai University of Traditional Chinese Medicine, 1200 Cailun Road, Shanghai 201203, China.
  • Li J; Basic Medicine College, Shanghai University of Traditional Chinese Medicine, 1200 Cailun Road, Shanghai 201203, China.
  • Shi YL; Basic Medicine College, Shanghai University of Traditional Chinese Medicine, 1200 Cailun Road, Shanghai 201203, China.
  • Li JC; Basic Medicine College, Shanghai University of Traditional Chinese Medicine, 1200 Cailun Road, Shanghai 201203, China.
  • Cui J; Basic Medicine College, Shanghai University of Traditional Chinese Medicine, 1200 Cailun Road, Shanghai 201203, China.
  • Xu JT; Basic Medicine College, Shanghai University of Traditional Chinese Medicine, 1200 Cailun Road, Shanghai 201203, China.
Article en En | MEDLINE | ID: mdl-35222674
Study on the objectivity of pulse diagnosis is inseparable from the instruments to obtain the pulse waves. The single-pulse diagnostic instrument is relatively mature in acquiring and analysing pulse waves, but the pulse information captured by single-pulse diagnostic instrument is limited. The sensor arrays can simulate rich sense of the doctor's fingers and catch multipoint and multiparameter array signals. How to analyse the acquired array signals is still a major problem in the objective research of pulse diagnosis. The goal of this study was to establish methods for analysing arrayed pulse waves and preliminarily apply them in hypertensive disorders. While a sensor array can be used for the real-time monitoring of twelve pulse wave channels, for each subject in this study, only the pulse wave signals of the left hand at the "guan" location were obtained. We calculated the average pulse wave (APW) per channel over a thirty-second interval. The most representative pulse wave (MRPW) and the APW were matched by their correlation coefficient (CC). The features of the MRPW and the features that corresponded to the array pulse volume (APV) parameters were identified manually. Finally, a clinical trial was conducted to detect these feature performance indicators in patients with hypertensive disorders. The independent-samples t-tests and the Mann-Whitney U-tests were performed to assess the differences in these pulse parameters between the healthy and hypertensive groups. We found that the radial passage (RP) APV h1, APV h3, APV h4, APV h3/h1 (P < 0.01), and APV h4/h1 (P < 0.05) were significantly higher in the hypertensive group than in the healthy group; the intermediate passage (IP) APV h4, APV h3/h1 (P < 0.05), and APV h4/h1 (P < 0.01) and the mean APV h3, APV h3/h1 (P < 0.05), and APV h4/h1 (P < 0.01) were significantly higher in the hypertensive group than in the healthy group, and the ulnar passage (UP) APV h4/h1 (P < 0.05) was clearly elevated in the hypertensive group. These results provide a preliminary validation of this novel approach for determining the APV by arrayed pulse wave analysis. In conclusion, we identified effective indicators of hypertensive vascular function. Traditional Chinese medicine (TCM) pulses comprise multidimensional information, and a sensor array could provide a better indication of TCM pulse characteristics. In this study, the validation of the arrayed pulse wave analysis demonstrates that the APV can reliably mirror TCM pulse characteristics.

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Tipo de estudio: Prognostic_studies Idioma: En Revista: Evid Based Complement Alternat Med Año: 2022 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Tipo de estudio: Prognostic_studies Idioma: En Revista: Evid Based Complement Alternat Med Año: 2022 Tipo del documento: Article País de afiliación: China