Your browser doesn't support javascript.
loading
Activation of the deep hip muscles can change the direction of loading at the hip.
Meinders, Evy; Pizzolato, Claudio; Gonçalves, Basílio; Lloyd, David G; Saxby, David J; Diamond, Laura E.
Afiliación
  • Meinders E; Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Menzies Health Institute Queensland, Griffith University, Gold Coast, Queensland 4222, Australia; Advanced Design and Prototyping Technologies Institute (ADaPT), Griffith University, Gold Coast, Queensland 4222, Australia; School
  • Pizzolato C; Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Menzies Health Institute Queensland, Griffith University, Gold Coast, Queensland 4222, Australia; Advanced Design and Prototyping Technologies Institute (ADaPT), Griffith University, Gold Coast, Queensland 4222, Australia; School
  • Gonçalves B; Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Menzies Health Institute Queensland, Griffith University, Gold Coast, Queensland 4222, Australia; Advanced Design and Prototyping Technologies Institute (ADaPT), Griffith University, Gold Coast, Queensland 4222, Australia; School
  • Lloyd DG; Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Menzies Health Institute Queensland, Griffith University, Gold Coast, Queensland 4222, Australia; Advanced Design and Prototyping Technologies Institute (ADaPT), Griffith University, Gold Coast, Queensland 4222, Australia; School
  • Saxby DJ; Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Menzies Health Institute Queensland, Griffith University, Gold Coast, Queensland 4222, Australia; Advanced Design and Prototyping Technologies Institute (ADaPT), Griffith University, Gold Coast, Queensland 4222, Australia; School
  • Diamond LE; Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Menzies Health Institute Queensland, Griffith University, Gold Coast, Queensland 4222, Australia; Advanced Design and Prototyping Technologies Institute (ADaPT), Griffith University, Gold Coast, Queensland 4222, Australia; School
J Biomech ; 135: 111019, 2022 04.
Article en En | MEDLINE | ID: mdl-35248802

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Muslo / Cadera Límite: Adult / Female / Humans / Male Idioma: En Revista: J Biomech Año: 2022 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Muslo / Cadera Límite: Adult / Female / Humans / Male Idioma: En Revista: J Biomech Año: 2022 Tipo del documento: Article