Your browser doesn't support javascript.
loading
The medial window technique as a salvage method to insert C2 pedicle screw in the case of a high-riding vertebral artery or narrow pedicle: a technical note and case series.
Lee, Dong-Ho; Park, Sehan; Cho, Jae Hwan; Hwang, Chang Ju; Lee, Hyung Rae; Seok, Sang Yun; Lee, Choon Sung.
Afiliación
  • Lee DH; Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
  • Park S; Department of Orthopedic Surgery, Dongguk University Ilsan Hospital, 14 Siksadong, Ilsandonggu, , Goyangsi, Gyeonggido, 411-773, Republic of Korea. birdone86@gmail.com.
  • Cho JH; Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
  • Hwang CJ; Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
  • Lee HR; Department of Orthopedic Surgery, Uijeongbu Eulji Medical Center, Uijungbusi, Gyeonggido, Republic of Korea.
  • Seok SY; Department of Orthopedic Surgery, Daejeon Eulji Medical Center, Daejoensi, Republic of Korea.
  • Lee CS; Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
Eur Spine J ; 31(5): 1251-1259, 2022 05.
Article en En | MEDLINE | ID: mdl-35249142
ABSTRACT

PURPOSE:

To describe the safety and feasibility of C2 medial window screw (C2MWS) as an alternative salvage method for C2 pedicle screws in cases of high-riding vertebral artery (HRVA) or narrow pedicle.

METHODS:

The C2MWS technique involves screw insertion by intentionally breaching the medial cortex of the pedicle to avoid vertebral artery injury. Twelve patients who underwent C2 screw insertion via the C2MWS were retrospectively reviewed. C2MWS was indicated in cases of high-riding vertebral artery (HRVA) or narrow pedicle (pedicle width ≤ 4 mm). The width of the canal breach by screw, vertebral artery groove (VAG) breach, solid fusion, neck pain visual analogue scale (VAS) score, and Japanese Orthopedic Association (JOA) score were assessed as outcome measurements.

RESULTS:

C2MWS was indicated due to both HRVA and narrow pedicle for 11 screws, narrow pedicle for one screw, and HRVA for two screws. No screw VAG breach or vertebral artery injury was noted postoperatively. The mean width of canal breach was 2.9 ± 1.3 mm. There were no cases demonstrating neurologic deterioration, and 11 patients (91.7%) demonstrated solid fusion at 1-year follow-up. Furthermore, neck pain VAS and JOA scores significantly improved after the surgery.

CONCLUSIONS:

The C2MWS technique can provide 3-column fixation while reliably avoiding VA injury. C2MWS could be considered as a salvage alternative method when the insertion of C2 pedicle screw is complicated by HRVA or a narrow pedicle, while there is a need to provide firmer fixation strength than that provided by pars or translaminar screws.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Fusión Vertebral / Tornillos Pediculares Tipo de estudio: Etiology_studies / Observational_studies Límite: Humans Idioma: En Revista: Eur Spine J Asunto de la revista: ORTOPEDIA Año: 2022 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Fusión Vertebral / Tornillos Pediculares Tipo de estudio: Etiology_studies / Observational_studies Límite: Humans Idioma: En Revista: Eur Spine J Asunto de la revista: ORTOPEDIA Año: 2022 Tipo del documento: Article