Your browser doesn't support javascript.
loading
Reliability in viscosity measurement of thickening agents for dysphagia management: Are results obtained by cone-and-plate rheometers reproducible between laboratories?
Kumai, Yasuhito; Suzuki, Ippei; Tousen, Yuko; Kondo, Takashi; Kayashita, Jun; Chiba, Tsuyoshi; Furusho, Tadasu; Takebayashi, Jun.
Afiliación
  • Kumai Y; National Institute of Health and Nutrition, National Institutes of Biomedical Innovation, Health and Nutrition, Tokyo, Japan.
  • Suzuki I; National Institute of Health and Nutrition, National Institutes of Biomedical Innovation, Health and Nutrition, Tokyo, Japan.
  • Tousen Y; National Institute of Health and Nutrition, National Institutes of Biomedical Innovation, Health and Nutrition, Tokyo, Japan.
  • Kondo T; National Institute of Health and Nutrition, National Institutes of Biomedical Innovation, Health and Nutrition, Tokyo, Japan.
  • Kayashita J; Department of Health Sciences, Prefectural University of Hiroshima, Hiroshima, Japan.
  • Chiba T; National Institute of Health and Nutrition, National Institutes of Biomedical Innovation, Health and Nutrition, Tokyo, Japan.
  • Furusho T; Department of International Food and Agricultural Science, Tokyo University of Agriculture, Tokyo, Japan.
  • Takebayashi J; National Institute of Health and Nutrition, National Institutes of Biomedical Innovation, Health and Nutrition, Tokyo, Japan.
J Texture Stud ; 53(2): 315-322, 2022 04.
Article en En | MEDLINE | ID: mdl-35249222
Viscosity measurement using a cone-and-plate rheometer is considered to provide an objective and reliable evaluation of thickening agents for dysphagia management. Here, we showed its measurement uncertainty in the context of an inter-laboratory study. Eight test samples (i.e., four viscosity standard liquids, one xanthan gum reagent powder, and three commercial thickening agent powders) were distributed to 10 laboratories in a blinded manner. According to the same standard operating procedure, each laboratory dissolved the xanthan gum or thickening agents at four concentrations (0.5-4.0 g/100 g) and then measured their viscosity (35-803 mPa∙s). As for the viscosity of the standard liquids, the grand means were 98-100% of the certified values, and the relative standard deviations for repeatability (RSDr ) and reproducibility (RSDR ) were ca. 1% and ca. 5%, respectively, suggesting good accuracy in the measurement process. On the other hand, as for the viscosity of the thickening agents, RSDr and RSDR were ca. 2-6% and ca. 5-8%, respectively; however, heterogeneity in the preparation process comprising a manual dissolving step may increase these to near 60%. Furthermore, RSDr and RSDR of estimated additive concentrations to achieve targeted viscosities (50-500 mPa∙s) based on concentration-viscosity curves were ca. 1-3% and ca. 3-5%, respectively, with a few exceptions. These findings suggest that a strictly standardized procedure provides reliable data on the viscosity measurements for thickening agents.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Trastornos de Deglución Límite: Humans Idioma: En Revista: J Texture Stud Año: 2022 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Trastornos de Deglución Límite: Humans Idioma: En Revista: J Texture Stud Año: 2022 Tipo del documento: Article País de afiliación: Japón