Your browser doesn't support javascript.
loading
Two-dimensional CT measurements enable assessment of body composition on head and neck CT.
Zopfs, David; Pinto Dos Santos, Daniel; Kottlors, Jonathan; Reimer, Robert P; Lennartz, Simon; Kloeckner, Roman; Schlaak, Max; Theurich, Sebastian; Kabbasch, Christoph; Schlamann, Marc; Große Hokamp, Nils.
Afiliación
  • Zopfs D; Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany. david.zopfs@uk-koeln.de.
  • Pinto Dos Santos D; Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany.
  • Kottlors J; Institute for Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany.
  • Reimer RP; Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany.
  • Lennartz S; Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany.
  • Kloeckner R; Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany.
  • Schlaak M; Department of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany.
  • Theurich S; Department of Dermatology, Venerology and Allergology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität, Berlin, Germany.
  • Kabbasch C; Cancer- and Immunometabolism Research Group, Gene Center LMU, Ludwig Maximilian University, Munich, Germany.
  • Schlamann M; Department of Medicine III, University Hospital LMU, Ludwig Maximilian University, Munich, Germany.
  • Große Hokamp N; Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany.
Eur Radiol ; 32(9): 6427-6434, 2022 Sep.
Article en En | MEDLINE | ID: mdl-35389049
ABSTRACT

OBJECTIVES:

The aim of this study was to evaluate whether simple 2D measurements in axial slices of head and neck CT examinations correlate with generally established measurements of body composition in abdominal CT at the height of the third lumbar vertebra and thus allow for an estimation of muscle and fat masses.

METHODS:

One hundred twenty-two patients who underwent concurrent CT of the head and neck and the abdomen between July 2016 and July 2020 were retrospectively included. For a subset of 30 patients, additional bioelectrical impedance analysis (BIA) was available. Areas of paraspinal muscles at the height of the third (C3) and fifth cervical vertebrae (C5) as well as the total cross-sectional area at the height of C3 and at the submandibular level were correlated with the results of abdominal measurements and BIA. Furthermore, intra- and interreader variabilities of all measurements were assessed.

RESULTS:

Regarding adipose tissue, good correlations were found between the total cross-sectional area of the patient's body at the submandibular level and at the height of C3 between both abdominal measurements and BIA results (r = 0.8-0.92; all p < 0.001). Regarding muscle, the total paraspinal muscle area at the height of C3 and C5 showed strong correlations with abdominal measurements and moderate to strong correlations with BIA results (r = 0.44-0.80; all p < 0.001), with the muscle area on C5 yielding slightly higher correlations.

CONCLUSIONS:

Body composition information can be obtained with comparable reliability from head and neck CT using simple biplanar measurements as from abdominal CT. KEY POINTS • The total paraspinal muscle area at the height of C3 and C5 correlates strongly with abdominal muscle mass. • The total cross-sectional area at the submandibular level and at the height of C3 shows good correlations with abdominal fat mass. • The described measurements facilitate a rapid, opportunistic assessment of relevant body composition parameters.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Composición Corporal / Tomografía Computarizada por Rayos X Tipo de estudio: Observational_studies Límite: Humans Idioma: En Revista: Eur Radiol Asunto de la revista: RADIOLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Composición Corporal / Tomografía Computarizada por Rayos X Tipo de estudio: Observational_studies Límite: Humans Idioma: En Revista: Eur Radiol Asunto de la revista: RADIOLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Alemania