Development and integration of photonic Doppler velocimetry as a diagnostic for radiation driven experiments on the Z-machine.
Swanson, K J; Jaar, G S; Mayes, D C; Mancini, R C; Ivanov, V V; Astanovitskiy, A L; Dmitriev, O; Klemmer, A W; De La Cruz, C; Dolan, D; Porwitzky, A; Loisel, G P; Bailey, J E.
Afiliación
  • Swanson KJ; Department of Physics, University of Nevada, Reno, Nevada 89557, USA.
  • Jaar GS; Department of Physics, University of Nevada, Reno, Nevada 89557, USA.
  • Mayes DC; Department of Physics, University of Nevada, Reno, Nevada 89557, USA.
  • Mancini RC; Department of Physics, University of Nevada, Reno, Nevada 89557, USA.
  • Ivanov VV; Department of Physics, University of Nevada, Reno, Nevada 89557, USA.
  • Astanovitskiy AL; Department of Physics, University of Nevada, Reno, Nevada 89557, USA.
  • Dmitriev O; Department of Physics, University of Nevada, Reno, Nevada 89557, USA.
  • Klemmer AW; Department of Physics, University of Nevada, Reno, Nevada 89557, USA.
  • De La Cruz C; Sandia National Laboratories, Albuquerque, New Mexico 87185, USA.
  • Dolan D; Sandia National Laboratories, Albuquerque, New Mexico 87185, USA.
  • Porwitzky A; Sandia National Laboratories, Albuquerque, New Mexico 87185, USA.
  • Loisel GP; Sandia National Laboratories, Albuquerque, New Mexico 87185, USA.
  • Bailey JE; Sandia National Laboratories, Albuquerque, New Mexico 87185, USA.
Rev Sci Instrum ; 93(4): 043502, 2022 Apr 01.
Article en En | MEDLINE | ID: mdl-35489931
Plasma density measurements are key to a wide variety of high-energy-density (HED) and laboratory astrophysics experiments. We present a creative application of photonic Doppler velocimetry (PDV) from which time- and spatially resolved electron density measurements can be made. PDV has been implemented for the first time in close proximity, ∼6 cm, to the high-intensity radiation flux produced by a z-pinch dynamic hohlraum on the Z-machine. Multiple PDV probes were incorporated into the photoionized gas cell platform. Two probes, spaced 4 mm apart, were used to assess plasma density and uniformity in the central region of the gas cell during the formation of the plasma. Electron density time histories with subnanosecond resolution were extracted from PDV measurements taken from the gas cells fielded with neon at 15 Torr. As well, a null shot with no gas fill in the cell was fielded. A major achievement was the low noise high-quality measurements made in the harsh environment produced by the mega-joules of x-ray energy emitted at the collapse of the z-pinch implosion. To evaluate time dependent radiation induced effects in the fiber optic system, two PDV noise probes were included on either side of the gas cell. The success of this alternative use of PDV demonstrates that it is a reliable, precise, and affordable new electron density diagnostic for radiation driven experiments and more generally HED experiments.

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Rev Sci Instrum Año: 2022 Tipo del documento: Article País de afiliación: Estados Unidos