Your browser doesn't support javascript.
loading
Safety of drug-eluting stents for stenting patent arterial duct in neonates.
Kurup, Harikrishnan K N; Gopalakrishnan, Arun; Sasikumar, Deepa; Krishnamoorthy, Kavassery M.
Afiliación
  • Kurup HKN; Department of Cardiology, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Thiruvananthapuram, Kerala695011, India.
  • Gopalakrishnan A; Department of Cardiology, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Thiruvananthapuram, Kerala695011, India.
  • Sasikumar D; Department of Cardiology, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Thiruvananthapuram, Kerala695011, India.
  • Krishnamoorthy KM; Department of Cardiology, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Thiruvananthapuram, Kerala695011, India.
Cardiol Young ; 33(3): 437-443, 2023 Mar.
Article en En | MEDLINE | ID: mdl-35508431
ABSTRACT

OBJECTIVES:

The primary objective was to evaluate the trend of blood sirolimus concentrations in neonates following ductal stenting. The long-term outcomes and incidence of infections were also evaluated.

METHODS:

Prospective open-label observational study in a tertiary referral centre over a 1-year period. Serum sirolimus levels were estimated at 1 hour and 24hrs post-stent insertion followed by 7 days in neonates who underwent ductal stenting. The trend in sirolimus levels, incidence of infections, complications and outcomes following ductal stenting were studied.

RESULTS:

Seven neonates with duct-dependent pulmonary circulation underwent ductal stenting at median age of 8.5 days and weight of 2.83kg. The average stent size was 3.5±0.4 mm, and average stent length was 16.3±5.1 mm. The mean sirolimus concentrations at 1 hour, 24 hours and 7 days were 41.3±6.9ng/ml, 15.4±7.1ng/ml and 3.1±0.85ng/ml respectively. Levels fell below therapeutic range for all patients by 7 days. Three patients had sepsis or necrotising enterocolitis, but responded well to antibiotics; 1 patient had aspiration related sudden death. There were no further events at a mean follow-up of 207 days, and 4 patients underwent elective surgery at 238 ± 81 days after ductal stenting.

CONCLUSIONS:

This study demonstrates applicability of drug-eluting stents for ductal stenting in newborns. Drug-eluting stents with abluminal drug delivery are associated with high sirolimus levels in initial hours but rapidly taper to negligible levels within a week of implantation. Neonates with high pre-procedure likelihood of infection developed sepsis but responded well to conservative management. The patency of drug-eluting ductal stents is preserved over long-term follow-up.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Conducto Arterioso Permeable / Stents Liberadores de Fármacos Tipo de estudio: Observational_studies Límite: Humans / Newborn Idioma: En Revista: Cardiol Young Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA / PEDIATRIA Año: 2023 Tipo del documento: Article País de afiliación: India

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Conducto Arterioso Permeable / Stents Liberadores de Fármacos Tipo de estudio: Observational_studies Límite: Humans / Newborn Idioma: En Revista: Cardiol Young Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA / PEDIATRIA Año: 2023 Tipo del documento: Article País de afiliación: India