Efficacy and Safety After Toric Posterior Chamber Implantable Collamer Lens and Toric Iris-Fixated Foldable Phakic Intraocular Lens for Myopic Astigmatism.
J Refract Surg ; 38(6): 339-347, 2022 Jun.
Article en En | MEDLINE | ID: mdl-35686710
ABSTRACT

PURPOSE:

To compare visual, refractive, and safety outcomes of toric posterior chamber Implantable Collamer Lens (T-ICL) (STAAR Surgical) and toric iris-fixated foldable phakic intraocular lens (IOL) (T-Artiflex; Ophtec BV) implantation for the correction of myopic astigmatism.

METHODS:

This retrospective cohort study included 312 eyes of 312 patients who had phakic IOL implantation for myopic astigmatism. Two groups were defined 205 eyes that underwent T-ICL implantation and 107 eyes that underwent T-Artiflex implantation. Safety, efficacy, and predictability outcomes were evaluated preoperatively and at 12 months postoperatively. Refractive and corneal astigmatic vector analysis were performed using the Alpins method.

RESULTS:

One year postoperatively, uncorrected distance visual acuity was 0.05 ± 0.18 (T-ICL) and 0.10 ± 0.16 (T-Artiflex) logMAR, with efficacy indexes of 1.16 ± 0.27 and 1.05 ± 0.31, respectively (P < .001). Safety indexes were 1.28 ± 0.30 and 1.21 ± 0.31, respectively (P = .04). Spherical equivalent was within ±0.50 diopters (D) of emmetropia in 165 (80.5%) and 88 (82.2%) eyes, respectively. Refractive astigmatic analysis showed an index of success of 0.28 ± 0.33 (T-ICL) and 0.31 ± 0.26 (T-Artiflex) (P = .07). Surgically induced corneal astigmatism was 0.48 ± 0.74 and 0.81 ± 0.61 D, respectively (P < .001). Mean endothelial loss was 1.11% and 2.05%, respectively (P = .42). Six (2.9%) eyes in the T-ICL group and 1 (0.9%) eye in the T-Artiflex group had phakic IOL repositioning due to significant misalignment. No vision-threatening complications occurred.

CONCLUSIONS:

Both the T-ICL and T-Artiflex groups showed high visual and refractive efficacy with a good safety profile for the correction of myopic astigmatism. T-ICL implantation demonstrated significantly better efficacy and safety indexes after 12 months. Vector analysis showed similar refractive astigmatic correction in both groups, but T-Artiflex implantation revealed higher surgically induced corneal astigmatism. [J Refract Surg. 2022;38(6)339-347.].
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Astigmatismo / Lentes Intraoculares Fáquicas / Miopía Tipo de estudio: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: J Refract Surg Asunto de la revista: OFTALMOLOGIA Año: 2022 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Astigmatismo / Lentes Intraoculares Fáquicas / Miopía Tipo de estudio: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: J Refract Surg Asunto de la revista: OFTALMOLOGIA Año: 2022 Tipo del documento: Article