Your browser doesn't support javascript.
loading
Improving immunoassay detection accuracy of anti-SARS-CoV-2 antibodies through dual modality validation.
Ma, Yuhao; To, Daniel; Zeng, Jie; Shoute, Lian C T; Wu, Meng; Babiuk, Shawn; Zhuo, Ran; Charlton, Carmen; Kanji, Jamil N; Babiuk, Lorne; Chen, Jie.
Afiliación
  • Ma Y; Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB, T6G 2V4, Canada.
  • To D; Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB, T6G 2V4, Canada.
  • Zeng J; Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB, T6G 2V4, Canada.
  • Shoute LCT; Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB, T6G 2V4, Canada.
  • Wu M; Department of Chemical and Materials Engineering, University of Alberta, Edmonton, AB, T6G 2R3, Canada.
  • Babiuk S; National Centre for Foreign Animal Disease, Canadian Food Inspection Agency, Winnipeg, MB, Canada.
  • Zhuo R; Department of Immunology, University of Manitoba, Winnipeg, MB, Canada.
  • Charlton C; Public Health Laboratory, Alberta Precision Laboratories, Calgary, AB, Canada.
  • Kanji JN; Department of Laboratory Medicine and Pathology, University of Alberta, Edmonton, AB, T6G 2B7, Canada.
  • Babiuk L; Public Health Laboratory, Alberta Precision Laboratories, Calgary, AB, Canada.
  • Chen J; Li Ka Shing Institute for Virology, University of Alberta, Edmonton, AB, Canada.
Biosens Bioelectron X ; 11: 100176, 2022 Sep.
Article en En | MEDLINE | ID: mdl-35692737
A novel test strategy is proposed with dual-modality detection techniques for COVID-19 antibody detection. The full-length S protein of SARS-CoV-2 was chemically immobilized on a glass surface to capture anti-SARS-CoV-2 IgG in patient serum and was detected through either Electrochemical Impedance Spectroscopy (EIS) or fluorescence imaging with labeled secondary antibodies. Gold nanoparticles conjugated with protein G were used as the probe and the bound GNP-G was detected through EIS measurements. Anti-human-IgG conjugated with the fluorescent tag Alexa Fluor 488 was used as the probe for fluorescence imaging. Clinical SARS-CoV-2 IgG positive serum and negative controls were used to validate both modalities. For fluorescence-based detection, a high sensitivity was noticed with a quantification range of 0.01-0.1 A.U.C. and a LOD of 0.004 A.U.C. This study demonstrates the possibility of utilizing different measurement techniques in conjunction for improved COVID-19 serology testing.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Biosens Bioelectron X Año: 2022 Tipo del documento: Article País de afiliación: Canadá

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Biosens Bioelectron X Año: 2022 Tipo del documento: Article País de afiliación: Canadá