Influence of pecking frequency at working length on the volume of apically extruded debris: A micro-computed tomography analysis.
Wang, Li-Xiao; Chen, Hui; Lin, Rui-Tian; Gu, Li-Sha.
Afiliación
  • Wang LX; Hospital of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong, China.
  • Chen H; Guangdong Provincial Key Laboratory of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong, China.
  • Lin RT; Hospital of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong, China.
  • Gu LS; Guangdong Provincial Key Laboratory of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong, China.
J Dent Sci ; 17(3): 1274-1280, 2022 Jul.
Article en En | MEDLINE | ID: mdl-35784137
Background/purpose: There is no consensus to date on how many repetitive pecking motions at working length (WL) should be regarded as optimal during instrumentation. Therefore, this study aimed to evaluate the effect of pecking frequency at WL on the volume of apically extruded debris using three single-file systems in curved, oval-shaped canals. Materials and methods: Forty-five single-rooted mandibular premolars with curved, oval-shaped canals were prescanned by micro-computed tomography, anatomically paired-matched, and randomly divided among three groups (n = 15 each): Reciproc Blue (RB), WaveOne Gold (WOG) and XP-endo Shaper (XPS). Samples were embedded in agarose gel to collect extruded debris. After preparation to the WL, each sample was rescanned after one, two, four, 10, and 20 pecking motions at WL, respectively. The debris volume was innovatively calculated by a modification of an existing method using micro-computed tomography. The apical preparation size was also measured. Data were compared using a two-way repeated-measures analysis of variance. Results: All single-file systems extruded debris apically, irrespective of the pecking frequency at WL. The extruded debris volume correlated positively with the minor foramen size (P < 0.05); both increased with pecking frequency for each single-file system (P < 0.05). The minor foramen size corresponded to the instrument tip size when reaching the WL once. Conclusion: To produce less debris extrusion and obtain a predictable foramen size corresponding to the instrument tip size, a single pecking motion may be preferred when using single-file systems. Caution should be exercised when applying the current results to clinical situations.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: J Dent Sci Año: 2022 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: J Dent Sci Año: 2022 Tipo del documento: Article País de afiliación: China