Your browser doesn't support javascript.
loading
Cross-site harmonization of multi-shell diffusion MRI measures based on rotational invariant spherical harmonics (RISH).
De Luca, Alberto; Karayumak, Suheyla Cetin; Leemans, Alexander; Rathi, Yogesh; Swinnen, Stephan; Gooijers, Jolien; Clauwaert, Amanda; Bahr, Roald; Sandmo, Stian Bahr; Sochen, Nir; Kaufmann, David; Muehlmann, Marc; Biessels, Geert-Jan; Koerte, Inga; Pasternak, Ofer.
Afiliación
  • De Luca A; Department of Neurology, UMC Utrecht Brain Center, University Medical Center Utrecht, Utrecht, the Netherlands; PROVIDI Lab, Image Sciences Institute, University Medical Center Utrecht, Utrecht, the Netherlands. Electronic address: a.deluca-2@umcutrecht.nl.
  • Karayumak SC; Brigham and Women's Hospital, Harvard Medical School, Boston, MA, United States.
  • Leemans A; PROVIDI Lab, Image Sciences Institute, University Medical Center Utrecht, Utrecht, the Netherlands.
  • Rathi Y; Brigham and Women's Hospital, Harvard Medical School, Boston, MA, United States.
  • Swinnen S; Movement Control and Neuroplasticity Research Group, KU Leuven, Leuven, Belgium; KU Leuven Brain Institute (LBI), Leuven, Belgium.
  • Gooijers J; Movement Control and Neuroplasticity Research Group, KU Leuven, Leuven, Belgium; KU Leuven Brain Institute (LBI), Leuven, Belgium.
  • Clauwaert A; Movement Control and Neuroplasticity Research Group, KU Leuven, Leuven, Belgium; KU Leuven Brain Institute (LBI), Leuven, Belgium.
  • Bahr R; Oslo Sports Trauma Research Center, Norwegian School of Sport Sciences, Oslo, Norway.
  • Sandmo SB; Oslo Sports Trauma Research Center, Norwegian School of Sport Sciences, Oslo, Norway.
  • Sochen N; Department of Applied Mathematics, Tel Aviv University, Tel Aviv, Israel; Sagol School of Neuroscience, Tel Aviv University, Tel Aviv, Israel.
  • Kaufmann D; Radiology Department, Charite University Hospital, Berlin, Germany.
  • Muehlmann M; Department of Radiology, Ludwig-Maximilians-Universität, Munich, Germany.
  • Biessels GJ; Department of Neurology, UMC Utrecht Brain Center, University Medical Center Utrecht, Utrecht, the Netherlands.
  • Koerte I; Brigham and Women's Hospital, Harvard Medical School, Boston, MA, United States; cBRAIN, Department of Child and Adolescent Psychiatry, Ludwig-Maximilians-Universität, Munich, Germany.
  • Pasternak O; Brigham and Women's Hospital, Harvard Medical School, Boston, MA, United States.
Neuroimage ; 259: 119439, 2022 10 01.
Article en En | MEDLINE | ID: mdl-35788044
ABSTRACT
Quantification methods based on the acquisition of diffusion magnetic resonance imaging (dMRI) with multiple diffusion weightings (e.g., multi-shell) are becoming increasingly applied to study the in-vivo brain. Compared to single-shell data for diffusion tensor imaging (DTI), multi-shell data allows to apply more complex models such as diffusion kurtosis imaging (DKI), which attempts to capture both diffusion hindrance and restriction effects, or biophysical models such as NODDI, which attempt to increase specificity by separating biophysical components. Because of the strong dependence of the dMRI signal on the measurement hardware, DKI and NODDI metrics show scanner and site differences, much like other dMRI metrics. These effects limit the implementation of multi-shell approaches in multicenter studies, which are needed to collect large sample sizes for robust analyses. Recently, a post-processing technique based on rotation invariant spherical harmonics (RISH) features was introduced to mitigate cross-scanner differences in DTI metrics. Unlike statistical harmonization methods, which require repeated application to every dMRI metric of choice, RISH harmonization is applied once on the raw data, and can be followed by any analysis. RISH features harmonization has been tested on DTI features but not its generalizability to harmonize multi-shell dMRI. In this work, we investigated whether performing the RISH features harmonization of multi-shell dMRI data removes cross-site differences in DKI and NODDI metrics while retaining longitudinal effects. To this end, 46 subjects underwent a longitudinal (up to 3 time points) two-shell dMRI protocol at 3 imaging sites. DKI and NODDI metrics were derived before and after harmonization and compared both at the whole brain level and at the voxel level. Then, the harmonization effects on cross-sectional and on longitudinal group differences were evaluated. RISH features averaged for each of the 3 sites exhibited prominent between-site differences in the frontal and posterior part of the brain. Statistically significant differences in fractional anisotropy, mean diffusivity and mean kurtosis were observed both at the whole brain and voxel level between all the acquisition sites before harmonization, but not after. The RISH method also proved effective to harmonize NODDI metrics, particularly in white matter. The RISH based harmonization maintained the magnitude and variance of longitudinal changes as compared to the non-harmonized data of all considered metrics. In conclusion, the application of RISH feature based harmonization to multi-shell dMRI data can be used to remove cross-site differences in DKI metrics and NODDI analyses, while retaining inherent relations between longitudinal acquisitions.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Imagen de Difusión Tensora / Sustancia Blanca Tipo de estudio: Clinical_trials / Observational_studies / Prevalence_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Neuroimage Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2022 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Imagen de Difusión Tensora / Sustancia Blanca Tipo de estudio: Clinical_trials / Observational_studies / Prevalence_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Neuroimage Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2022 Tipo del documento: Article