Your browser doesn't support javascript.
loading
Thiacalix[4]arene-based complex with Co(II) ions as electrode modifier for simultaneous electrochemical determination of Cd(II), Pb(II), and Cu(II).
Li, Xiang-Ting; Niu, Xia; Yang, Jin; Pei, Wen-Yuan; Ma, Jian-Fang.
Afiliación
  • Li XT; Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Department of Chemistry, Northeast Normal University, Changchun, 130024, China.
  • Niu X; Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Department of Chemistry, Northeast Normal University, Changchun, 130024, China.
  • Yang J; Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Department of Chemistry, Northeast Normal University, Changchun, 130024, China. yangj808@nenu.edu.cn.
  • Pei WY; Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Department of Chemistry, Northeast Normal University, Changchun, 130024, China.
  • Ma JF; Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Department of Chemistry, Northeast Normal University, Changchun, 130024, China. majf247@nenu.edu.cn.
Mikrochim Acta ; 189(9): 344, 2022 08 24.
Article en En | MEDLINE | ID: mdl-36001162
ABSTRACT
A complex [Co4(TCTA)2(H2O)8]∙10H2O (Co-TCTA) based on thiacalix[4]arene derivative has been synthesized for the first time using the solvothermal method. The glassy carbon electrode (GCE) modified with Co-TCTA (Co-TCTA/GCE) could simultaneously determine Cd2+, Pb2+, and Cu2+ at around - 0.75 V, - 0.60 V, and - 0.10 V (vs. ref. Ag/AgCl) and had good stability, selectivity, and reproducibility with relative standard deviation (RSD) of 4.4% for Cd2+, 1.4% for Pb2+, and 5.4% for Cu2+. Co-TCTA/GCE showed wide linear range of 0.4-8.0 µM for Cd2+, 0.4-7.0 µM for Pb2+, and 0.6-6.0 µM for Cu2+ when three ions were determined simultaneously. The limits of detection (LODs) of Cd2+, Pb2+, and Cu2+ were 0.071 µM, 0.022 µM, and 0.021 µM, respectively. Moreover, the sensor was used to determine three ions in lake water sample with satisfactory recoveries of 93.6-93.8% for Cd2+, 93.8-103.3% for Pb2+ and 94.6-95.3% for Cu2+. The good adsorption capacity of Co-TCTA and Co(II)/Co(0) circular mechanism on the surface of the electrode were proposed to enhance the electrochemical signals. This work enriched the theoretical research on the complexes for the determination of heavy metal ions.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Cadmio / Plomo Idioma: En Revista: Mikrochim Acta Año: 2022 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Cadmio / Plomo Idioma: En Revista: Mikrochim Acta Año: 2022 Tipo del documento: Article País de afiliación: China