Your browser doesn't support javascript.
loading
High-responsivity operation of quantum cascade detectors at 9 µm.
Opt Express ; 30(22): 40188-40195, 2022 Oct 24.
Article en En | MEDLINE | ID: mdl-36298955
ABSTRACT
Quantum cascade detectors (QCDs) are devices operating at zero external bias with a low dark-current. They show linear detection and high saturation intensities, making them suitable candidates for heterodyne detection in long-wave infrared (LWIR) free space optical communication systems. We present an approach to mitigate the performance limitation at long wavelengths, by a comparison of similar single and multi-period QCDs for optimizing their responsivity and noise behaviour. Our InGaAs/InAlAs/InP ridge QCDs are designed for operation at λ = 9.124 µm. Optical waveguide simulations support the accurate optical characterization. A detailed device analysis reveals room-temperature responsivities of 111 mA/W for the 15-period and 411 mA/W for the single-period device.

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Opt Express Asunto de la revista: OFTALMOLOGIA Año: 2022 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Opt Express Asunto de la revista: OFTALMOLOGIA Año: 2022 Tipo del documento: Article