[A pleural puncture gone wrong]. / 5 minutes pour apprendre - Une ponction pleurale qui tourne mal.
Rev Med Suisse
; 18(806): 2301-2302, 2022 Nov 30.
Article
en Fr
| MEDLINE
| ID: mdl-36448953
ABSTRACT
A patient with a paraneoplastic effusion presented with respiratory distress one hour after a 2 500 ml pleural aspiration performed at noon. A chest X-ray shows signs of unilateral pulmonary oedema. Re-expansion pulmonary oedema is a rare complication. Oxygen therapy is usually sufficient. It is advisable not to perform this procedure outside normal hours and to withdraw a maximum of 1 500 ml at a time.
Texto completo:
1
Colección:
01-internacional
Banco de datos:
MEDLINE
Asunto principal:
Edema Pulmonar
Límite:
Humans
Idioma:
Fr
Revista:
Rev Med Suisse
Asunto de la revista:
MEDICINA
Año:
2022
Tipo del documento:
Article