Your browser doesn't support javascript.
loading
Comparison of out-of-field normal tissue dose estimates for pencil beam scanning proton therapy: MCNP6, PHITS, and TOPAS.
Griffin, Keith T; Yeom, Yeon Soo; Mille, Matthew M; Lee, Choonik; Jung, Jae Won; Hertel, Nolan E; Lee, Choonsik.
Afiliación
  • Griffin KT; Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Rockville, MD, United States of America.
  • Yeom YS; George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, United States of America.
  • Mille MM; Department of Radiation Convergence Engineering, Yonsei University, Wonju, Republic of Korea.
  • Lee C; Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Rockville, MD, United States of America.
  • Jung JW; Department of Radiation Oncology, University of Michigan, Ann Arbor, MI, United States of America.
  • Hertel NE; Department of Physics, East Carolina University, Greenville, NC, United States of America.
  • Lee C; George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, United States of America.
Biomed Phys Eng Express ; 9(1)2022 12 23.
Article en En | MEDLINE | ID: mdl-36562506
ABSTRACT
Monte Carlo (MC) methods are considered the gold-standard approach to dose estimation for normal tissues outside the treatment field (out-of-field) in proton therapy. However, the physics of secondary particle production from high-energy protons are uncertain, particularly for secondary neutrons, due to challenges in performing accurate measurements. Instead, various physics models have been developed over the years to reenact these high-energy interactions based on theory. It should thus be acknowledged that MC users must currently accept some unknown uncertainties in out-of-field dose estimates. In the present study, we compared three MC codes (MCNP6, PHITS, and TOPAS) and their available physics models to investigate the variation in out-of-field normal tissue dosimetry for pencil beam scanning proton therapy patients. Total yield and double-differential (energy and angle) production of two major secondary particles, neutrons and gammas, were determined through irradiation of a water phantom at six proton energies (80, 90, 100, 110, 150, and 200 MeV). Out-of-field normal tissue doses were estimated for intracranial irradiations of 1-, 5-, and 15-year-old patients using whole-body computational phantoms. Notably, the total dose estimates for each out-of-field organ varied by approximately 25% across the three codes, independent of its distance from the treatment volume. Dose discrepancies amongst the codes were linked to the utilized physics model, which impacts the characteristics of the secondary radiation field. Using developer-recommended physics, TOPAS produced both the highest neutron and gamma doses to all out-of-field organs from all examined conditions; this was linked to its highest yields of secondary particles and second hardest energy spectra. Subsequent results when using other physics models found reduced yields and energies, resulting in lower dose estimates. Neutron dose estimates were the most impacted by physics model choice, and thus the variation in out-of-field dose estimates may be even larger than 25% when considering biological effectiveness.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Terapia de Protones Tipo de estudio: Health_economic_evaluation / Prognostic_studies Límite: Humans Idioma: En Revista: Biomed Phys Eng Express Año: 2022 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Terapia de Protones Tipo de estudio: Health_economic_evaluation / Prognostic_studies Límite: Humans Idioma: En Revista: Biomed Phys Eng Express Año: 2022 Tipo del documento: Article País de afiliación: Estados Unidos