Your browser doesn't support javascript.
loading
NiFe-based Prussian blue analogue nanopolygons hybridized with functionalized glyoxal polymer as a voltammetric platform for the determination of amisulpride in biological samples.
El-Zahry, Marwa R; Ali, Marwa F B.
Afiliación
  • El-Zahry MR; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Assiut University, Assiut, 71526, Egypt. marwazahry@aun.edu.eg.
  • Ali MFB; Pharmaceutical Chemistry Department, Faculty of Pharmacy, Badr University in Assiut, Assiut, 2014101, Egypt. marwazahry@aun.edu.eg.
Anal Bioanal Chem ; 415(8): 1559-1570, 2023 Mar.
Article en En | MEDLINE | ID: mdl-36807994
ABSTRACT
A novel voltammetric platform based on pencil graphite electrode (PGE) modification has been proposed, containing bimetallic (NiFe) Prussian blue analogue nanopolygons decorated with electro-polymerized glyoxal polymer nanocomposites (p-DPG NCs@NiFe PBA Ns/PGE). Cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and square wave voltammetry (SWV) were utilized to investigate the electrochemical performance of the proposed sensor. The analytical response of p-DPG NCs@NiFe PBA Ns/PGE was evaluated through the quantity of amisulpride (AMS), one of the most common antipsychotic drugs. Under the optimized experimental and instrumental conditions, the method showed linearity over the range from 0.5 to 15 × 10-8 mol L-1 with a good correlation coefficient (R = 0.9995) and a low detection limit (LOD) reached, 1.5 nmol L-1, with excellent relative standard deviation for human plasma and urine samples. The interference effect of some potentially interfering substances was negligible, and the sensing platform demonstrated an outstanding reproducibility, stability, and reusability. As a first trial, the proposed electrode aimed to shed light on the AMS oxidation mechanism, where the oxidation mechanism was monitored and elucidated using the FTIR technique. It was also found that the prepared p-DPG NCs@NiFe PBA Ns/PGE platform had promising applications for the simultaneous determination of AMS in the presence of some co-administered COVID-19 drugs, which could be attributed to the large active surface area, and high conductivity of bimetallic nanopolygons.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: COVID-19 / Grafito Límite: Humans Idioma: En Revista: Anal Bioanal Chem Año: 2023 Tipo del documento: Article País de afiliación: Egipto

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: COVID-19 / Grafito Límite: Humans Idioma: En Revista: Anal Bioanal Chem Año: 2023 Tipo del documento: Article País de afiliación: Egipto