Your browser doesn't support javascript.
loading
A false decrease in the automatically measured atrial pacing threshold when using the automatic pacing threshold adjustment algorithm.
Ishihara, Yu; Noma, Takahisa; Takeuchi, Masaki; Shimokawa, Kohei; Shiraishi, Yoji; Inoue, Tomoko; Ohara, Minako; Ishikawa, Kaori; Minamino, Tetsuo.
Afiliación
  • Ishihara Y; Department of Cardiorenal and Cerebrovascular Medicine, Faculty of Medicine, Kagawa University, Takamatsu, Kagawa, Japan.
  • Noma T; Department of Cardiorenal and Cerebrovascular Medicine, Faculty of Medicine, Kagawa University, Takamatsu, Kagawa, Japan.
  • Takeuchi M; Department of Clinical Engineering, Kagawa University Hospital, Takamatsu, Kagawa, Japan.
  • Shimokawa K; Department of Clinical Engineering, Kagawa University Hospital, Takamatsu, Kagawa, Japan.
  • Shiraishi Y; Department of Clinical Engineering, Kagawa University Hospital, Takamatsu, Kagawa, Japan.
  • Inoue T; Department of Cardiorenal and Cerebrovascular Medicine, Faculty of Medicine, Kagawa University, Takamatsu, Kagawa, Japan.
  • Ohara M; Department of Cardiorenal and Cerebrovascular Medicine, Faculty of Medicine, Kagawa University, Takamatsu, Kagawa, Japan.
  • Ishikawa K; Department of Cardiorenal and Cerebrovascular Medicine, Faculty of Medicine, Kagawa University, Takamatsu, Kagawa, Japan.
  • Minamino T; Department of Cardiorenal and Cerebrovascular Medicine, Faculty of Medicine, Kagawa University, Takamatsu, Kagawa, Japan.
Pacing Clin Electrophysiol ; 46(11): 1375-1378, 2023 11.
Article en En | MEDLINE | ID: mdl-36860199
ABSTRACT
Automatic pacing threshold adjustment algorithms and remote monitoring are widely used to improve the utility of pacemakers and ensure patient safety. However, healthcare providers involved in the management of permanent pacemakers should know the potential pitfalls of these functions. In this report, we present a case of atrial pacing failure induced by the automatic pacing threshold adjustment algorithm that went unnoticed even under remote monitoring.