Your browser doesn't support javascript.
loading
Multi-Allergen Quantification in Food Using Concatemer-Based Isotope Dilution Mass Spectrometry: An Interlaboratory Study.
Gavage, Maxime; Van Vlierberghe, Kaatje; Dieu, Marc; Renard, Patsy; Arnould, Thierry; Gevaert, Kris; De Loose, Marc; Van Poucke, Christof; Huet, Anne-Catherine; Gillard, Nathalie.
Afiliación
  • Gavage M; CER Groupe, 8 Rue du Point du Jour, 6900 Marloie, Belgium.
  • Van Vlierberghe K; ILVO Flanders Research Institute for Agriculture, Fisheries and Food, Technology and Food Science Unit, 370 Brusselsesteenweg, 9090 Melle, Belgium.
  • Dieu M; University of Namur, Laboratory of Biochemistry and Cell Biology (URBC), Namur Research Institute for Life Sciences (NARILIS), 61 Rue de Bruxelles, 5000 Namur, Belgium.
  • Renard P; University of Namur, Laboratory of Biochemistry and Cell Biology (URBC), Namur Research Institute for Life Sciences (NARILIS), 61 Rue de Bruxelles, 5000 Namur, Belgium.
  • Arnould T; University of Namur, Laboratory of Biochemistry and Cell Biology (URBC), Namur Research Institute for Life Sciences (NARILIS), 61 Rue de Bruxelles, 5000 Namur, Belgium.
  • Gevaert K; VIB-UGent, Center for Medical Biotechnology, 75 Technologiepark-Zwijnaarde, 9052 Ghent, Belgium.
  • De Loose M; Ghent University, Department of Biomolecular Medicine, 75 Technologiepark-Zwijnaarde, 9052 Ghent, Belgium.
  • Van Poucke C; ILVO Flanders Research Institute for Agriculture, Fisheries and Food, Technology and Food Science Unit, 370 Brusselsesteenweg, 9090 Melle, Belgium.
  • Huet AC; ILVO Flanders Research Institute for Agriculture, Fisheries and Food, Technology and Food Science Unit, 370 Brusselsesteenweg, 9090 Melle, Belgium.
  • Gillard N; CER Groupe, 8 Rue du Point du Jour, 6900 Marloie, Belgium.
J AOAC Int ; 106(4): 886-898, 2023 Jul 17.
Article en En | MEDLINE | ID: mdl-36961330
BACKGROUND: Food allergen analysis is essential for the development of a risk-based approach for allergen management and labeling. MS has become a method of choice for allergen analysis, even if quantification remains challenging. Moreover, harmonization is still lacking between laboratories, while interlaboratory validation of analytical methods is necessary for such harmonization. OBJECTIVE: This interlaboratory study aimed to evaluate the potential of MS for food allergen detection and quantification using a standard addition quantification strategy and a stable isotope-labeled (SIL) concatemer as an internal standard. METHODS: In-house-produced test material (cookies), blank and incurred with four allergens (egg, milk, peanut, and hazelnut), allergen standards, an internal standard, and the complete methodology (including sample preparation and ultra-HPLC-MS/MS method) were provided to nine laboratories involved in the study. Method sensitivity and selectivity were evaluated with incurred test material and accuracy with spiked test material. Quantification was based on the standard addition strategy using certified reference materials as allergen protein standards and a SIL concatemer as an internal standard. RESULTS: All laboratories were able to detect milk, hazelnut, and peanut in the incurred cookies with sufficient sensitivity to reach the AOAC INTERNATIONAL Standard Method Performance Requirements (SMPR® 2016.002). Egg detection was more complicated due to food processing effects, yet five laboratories reached the sensitivity requirements. Recovery results were laboratory-dependent. Some milk and hazelnut peptides were quantified in agreement with SMPR 2016.002 by all participants. Furthermore, over 90% of the received quantification results agreed with SMPR 2016.002 for method precision. CONCLUSION: The encouraging results of this pioneering interlaboratory study represent an additional step towards harmonization among laboratories testing for allergens. HIGHLIGHTS: In this pioneering interlaboratory study, food allergens were analyzed by MS with characterized incurred and spiked test materials, calibrated with a certified reference material, and a single SIL concatemer used as an internal standard.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Espectrometría de Masas en Tándem / Hipersensibilidad a los Alimentos Límite: Humans Idioma: En Revista: J AOAC Int Año: 2023 Tipo del documento: Article País de afiliación: Bélgica

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Espectrometría de Masas en Tándem / Hipersensibilidad a los Alimentos Límite: Humans Idioma: En Revista: J AOAC Int Año: 2023 Tipo del documento: Article País de afiliación: Bélgica