Your browser doesn't support javascript.
loading
Development, stability-indicating assessment, and evaluation of influential method conditions using a full factorial design for the determination of Nintedanib esylate-related impurities.
Yenda, Parvateesam; Katari, Naresh Kumar; Satheesh, Balasubramanian; Gundla, Rambabu; Muchakayala, Siva Krishna; Rekulapally, Vijay Kumar.
Afiliación
  • Yenda P; Department of Chemistry, GITAM School of Science, GITAM deemed to be University, Hyderabad, India.
  • Katari NK; Analytical department, Slayback Pharma India LLP, Manjeera trinity corporate, JNTU, Hyderabad, India.
  • Satheesh B; Department of Chemistry, GITAM School of Science, GITAM deemed to be University, Hyderabad, India.
  • Gundla R; Analytical department, Slayback Pharma India LLP, Manjeera trinity corporate, JNTU, Hyderabad, India.
  • Muchakayala SK; Department of Chemistry, GITAM School of Science, GITAM deemed to be University, Hyderabad, India.
  • Rekulapally VK; Department of Chemistry, GITAM School of Science, GITAM deemed to be University, Hyderabad, India.
J Sep Sci ; 46(11): e2200770, 2023 Jun.
Article en En | MEDLINE | ID: mdl-36976154
ABSTRACT
The design of an appropriate analytical method for assessing the quality of pharmaceuticals requires a deep understanding of science, and risk evaluation approaches are appreciated. The current study discusses how a related substance method was developed for Nintedanib esylate. The best possible separation between the critical peak pairs was achieved using an X-Select charged surface hybrid Phenyl Hexyl (150 × 4.6) mm, 3.5 µm column. A mixture of water, acetonitrile, and methanol in mobile phase-A (702010) and mobile phase-B (207010), with 0.1% trifluoroacetic acid and 0.05% formic acid in both eluents. The set flow rate, wavelength, and injection volumes were 1.0 ml/min, 285 nm, and 5 µl, respectively, with gradient elution. The method conditions were validated as per regulatory requirements and United States Pharmacopeia general chapter < 1225 >. The correlation coefficient for all impurities from the linearity experiment was found to be > 0.999. The % relative standard deviation from the precision experiments ranged from 0.4 to 3.6. The mean %recovery from the accuracy study ranged from 92.5 to 106.5. Demonstrated the power of the stability-indicating method through degradation studies; the active drug component is more vulnerable to oxidation than other conditions. Final method conditions were further evaluated using a full-factorial design. The robust method conditions were identified using the graphical optimization from the design space.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Contaminación de Medicamentos / Indoles Tipo de estudio: Prognostic_studies Idioma: En Revista: J Sep Sci Año: 2023 Tipo del documento: Article País de afiliación: India

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Contaminación de Medicamentos / Indoles Tipo de estudio: Prognostic_studies Idioma: En Revista: J Sep Sci Año: 2023 Tipo del documento: Article País de afiliación: India