Your browser doesn't support javascript.
loading
A Quencher-Based Blood-Autofluorescence-Suppression Strategy Enables the Quantification of Trace Analytes in Whole Blood.
Yuwen, Zhiyang; Zeng, Qin; Ye, Qiaozhen; Zhao, Yixing; Zhu, Jingxuan; Chen, Kang; Liu, Hongwen; Yang, Ronghua.
Afiliación
  • Yuwen Z; Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research, Institute of Interdisciplinary Studies, College of Chemistry and Chemical Engineering, Hunan Normal University, 410082, Changsha, P. R. China.
  • Zeng Q; Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research, Institute of Interdisciplinary Studies, College of Chemistry and Chemical Engineering, Hunan Normal University, 410082, Changsha, P. R. China.
  • Ye Q; Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research, Institute of Interdisciplinary Studies, College of Chemistry and Chemical Engineering, Hunan Normal University, 410082, Changsha, P. R. China.
  • Zhao Y; Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research, Institute of Interdisciplinary Studies, College of Chemistry and Chemical Engineering, Hunan Normal University, 410082, Changsha, P. R. China.
  • Zhu J; Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research, Institute of Interdisciplinary Studies, College of Chemistry and Chemical Engineering, Hunan Normal University, 410082, Changsha, P. R. China.
  • Chen K; Department of Hepatobiliary Surgery, the First Affiliated Hospital of Hunan Normal University, Hunan Normal University, 410005, Changsha, P. R. China.
  • Liu H; Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research, Institute of Interdisciplinary Studies, College of Chemistry and Chemical Engineering, Hunan Normal University, 410082, Changsha, P. R. China.
  • Yang R; Department of Hepatobiliary Surgery, the First Affiliated Hospital of Hunan Normal University, Hunan Normal University, 410005, Changsha, P. R. China.
Angew Chem Int Ed Engl ; 62(25): e202302957, 2023 06 19.
Article en En | MEDLINE | ID: mdl-37102382
ABSTRACT
Precise quantification of trace components in whole blood via fluorescence is of great significance. However, the applicability of current fluorescent probes in whole blood is largely hindered by the strong blood autofluorescence. Here, we proposed a blood autofluorescence-suppressed sensing strategy to develop an activable fluorescent probe for quantification of trace analyte in whole blood. Based on inner filter effect, by screening fluorophores whose absorption overlapped with the emission of blood, a redshift BODIPY quencher with an absorption wavelength ranging from 600-700 nm was selected for its superior quenching efficiency and high brightness. Two 7-nitrobenzo[c] [1,2,5] oxadiazole ether groups were introduced onto the BODIPY skeleton for quenching its fluorescence and the response of H2 S, a gas signal molecule that can hardly be quantified because of its low concentration in whole blood. Such detection system shows a pretty low background signal and high signal-to-back ratio, the probe thus achieved the accurate quantification of endogenous H2 S in 20-fold dilution of whole blood samples, which is the first attempt of quantifying endogenous H2 S in whole blood. Moreover, this autofluorescence-suppressed sensing strategy could be expanded to other trace analytes detection in whole blood, which may accelerate the application of fluorescent probes in clinical blood test.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Compuestos de Boro / Colorantes Fluorescentes Idioma: En Revista: Angew Chem Int Ed Engl Año: 2023 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Compuestos de Boro / Colorantes Fluorescentes Idioma: En Revista: Angew Chem Int Ed Engl Año: 2023 Tipo del documento: Article