Your browser doesn't support javascript.
loading
Three-dimensional diffusion MRI using simultaneous multislab with blipped-CAIPI in a 4D k-space framework.
Liu, Simin; Zhang, Jieying; Shi, Diwei; Guo, Hua.
Afiliación
  • Liu S; Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China.
  • Zhang J; Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China.
  • Shi D; Center for Nano & Micro Mechanics, Department of Engineering Mechanics, Tsinghua University, Beijing, China.
  • Guo H; Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China.
Magn Reson Med ; 90(3): 978-994, 2023 09.
Article en En | MEDLINE | ID: mdl-37103910
ABSTRACT

PURPOSE:

To develop an efficient simultaneous multislab imaging method with blipped-controlled aliasing in parallel imaging (blipped-SMSlab) in a 4D k-space framework, and to demonstrate its efficacy in high-resolution diffusion MRI (dMRI). THEORY AND

METHODS:

First, the SMSlab 4D k-space signal expression is formulated, and the phase interferences from intraslab and interslab encodings on the same physical z-axis are analyzed. Then, the blipped-SMSlab dMRI sequence is designed, with blipped-controlled aliasing in parallel imaging (blipped-CAIPI) gradients for interslab encoding, and a 2D multiband accelerated navigator for inter-kz-shot phase correction. Third, strategies are developed to remove the phase interferences, by RF phase modulation and/or phase correction during reconstruction, thus decoupling intraslab and interslab encodings that are otherwise entangled. In vivo experiments are performed to validate the blipped-SMSlab method and preliminarily evaluate its performance in high-resolution dMRI compared with traditional 2D imaging.

RESULTS:

In the 4D k-space framework, interslab and intraslab phase interferences of blipped-SMSlab are successfully removed using the proposed strategies. Compared with non-CAIPI sampling, the blipped-SMSlab acquisition reduces the g-factor and g-factor-related SNR penalty by about 12%. In addition, in vivo experiments show the SNR advantage of blipped-SMSlab dMRI over traditional 2D dMRI for 1.3-mm and 1.0-mm isotropic resolution imaging with matched acquisition time.

CONCLUSION:

Removing interslab and intraslab phase interferences enables SMSlab dMRI with blipped-CAIPI in a 4D k-space framework. The proposed blipped-SMSlab dMRI is demonstrated to be more SNR-efficient than 2D dMRI and thus capable of high-quality, high-resolution fiber orientation detection.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Imagenología Tridimensional / Imagen de Difusión por Resonancia Magnética Límite: Humans Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2023 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Imagenología Tridimensional / Imagen de Difusión por Resonancia Magnética Límite: Humans Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2023 Tipo del documento: Article País de afiliación: China