Comparison of Accuracy of Freestyle Libre Pro and Medtronic iPro2 Continuous Glucose Monitoring Systems in Pregnancy.
Golla, Kiran Kumar; Gupta, Yashdeep; Goyal, Alpesh; Kalaivani, Mani; Kachhawa, Garima; Kulshrestha, Vidushi; Sharma, Aparna K; Meena, Jyoti; Bharti, Juhi; Sharma, Jai B; Dadhwal, Vatsla; Malhotra, Neena; Bhatla, Neerja; Tandon, Nikhil.
Afiliación
  • Golla KK; Department of Endocrinology and Metabolism, All India Institute of Medical Sciences, New Delhi, India.
  • Gupta Y; Department of Endocrinology and Metabolism, All India Institute of Medical Sciences, New Delhi, India.
  • Goyal A; Department of Endocrinology and Metabolism, All India Institute of Medical Sciences, New Delhi, India.
  • Kalaivani M; Department of Biostatistics, and All India Institute of Medical Sciences, New Delhi, India.
  • Kachhawa G; Department of Obstetrics and Gynaecology, All India Institute of Medical Sciences, New Delhi, India.
  • Kulshrestha V; Department of Obstetrics and Gynaecology, All India Institute of Medical Sciences, New Delhi, India.
  • Sharma AK; Department of Obstetrics and Gynaecology, All India Institute of Medical Sciences, New Delhi, India.
  • Meena J; Department of Obstetrics and Gynaecology, All India Institute of Medical Sciences, New Delhi, India.
  • Bharti J; Department of Obstetrics and Gynaecology, All India Institute of Medical Sciences, New Delhi, India.
  • Sharma JB; Department of Obstetrics and Gynaecology, All India Institute of Medical Sciences, New Delhi, India.
  • Dadhwal V; Department of Obstetrics and Gynaecology, All India Institute of Medical Sciences, New Delhi, India.
  • Malhotra N; Department of Obstetrics and Gynaecology, All India Institute of Medical Sciences, New Delhi, India.
  • Bhatla N; Department of Obstetrics and Gynaecology, All India Institute of Medical Sciences, New Delhi, India.
  • Tandon N; Department of Endocrinology and Metabolism, All India Institute of Medical Sciences, New Delhi, India.
Diabetes Technol Ther ; 25(8): 538-542, 2023 08.
Article en En | MEDLINE | ID: mdl-37129276
ABSTRACT
There are limited data on head-to-head performance of Freestyle Libre Pro (FSL-Pro) and blinded Medtronic iPro2 continuous glucose monitoring system in pregnancy. In this prospective observational study, women with hyperglycemia in pregnancy (n = 42) underwent simultaneous FSL-Pro and Medtronic iPro2 sensor insertion and self-monitoring of blood glucose using Contour Plus meter (reference). The overall mean absolute relative difference (MARD) for iPro2 and FSL-Pro systems were 8.0% ± 9.2% and 19.0% ± 12.7%, respectively. At hypoglycemic range, both sensors performed less accurately (MARD 18.0% and 16.8%, respectively), whereas iPro2 showed higher accuracy at euglycemic (8.2% and 19.3%, respectively) and hyperglycemic (6.8% and 18.0%, respectively) ranges. On Bland-Altman analysis, iPro2 and FSL-Pro underestimated glucose by 0.01 and 1.09 mmol/L, respectively. The ISO criteria were fulfilled for 88.5% and 44.9% of all values, respectively. To conclude, iPro2 was more accurate; however, both sensors demonstrated inaccuracy at hypoglycemic range, highlighting the need for refinements in the current generation of sensors to address this problem.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Glucemia / Diabetes Mellitus Tipo 1 Tipo de estudio: Observational_studies Límite: Female / Humans / Pregnancy Idioma: En Revista: Diabetes Technol Ther Asunto de la revista: ENDOCRINOLOGIA / TERAPEUTICA Año: 2023 Tipo del documento: Article País de afiliación: India

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Glucemia / Diabetes Mellitus Tipo 1 Tipo de estudio: Observational_studies Límite: Female / Humans / Pregnancy Idioma: En Revista: Diabetes Technol Ther Asunto de la revista: ENDOCRINOLOGIA / TERAPEUTICA Año: 2023 Tipo del documento: Article País de afiliación: India