Zero-Contrast Left Atrial Appendage Occlusion Using a Hybrid Echocardiography-Fluoroscopy Technique Without Iodinated Contrast.
Am J Cardiol
; 198: 53-55, 2023 07 01.
Article
en En
| MEDLINE
| ID: mdl-37201232
ABSTRACT
Contrast exposure during left atrial appendage occlusion may be harmful in those with chronic kidney disease or allergy. This single-center registry (n = 31) demonstrates the feasibility and safety of zero-contrast percutaneous left atrial appendage occlusion using echocardiography, fluoroscopy, and fusion imaging, with 100% procedural success and no device complications at 45 days.