The significance of coefficient of variation as a measure of hypoglycaemia risk and glycaemic control in real world users of the automated insulin delivery MiniMed 780G system.
Castañeda, Javier; Arrieta, Arcelia; van den Heuvel, Tim; Cohen, Ohad.
Afiliación
  • Castañeda J; Medtronic Bakken Research Center, Maastricht, The Netherlands.
  • Arrieta A; Medtronic Bakken Research Center, Maastricht, The Netherlands.
  • van den Heuvel T; Medtronic Bakken Research Center, Maastricht, The Netherlands.
  • Cohen O; Medtronic International Trading Sàrl, Tolochenaz, Switzerland.
Diabetes Obes Metab ; 25(9): 2545-2552, 2023 09.
Article en En | MEDLINE | ID: mdl-37246797
ABSTRACT

AIM:

Use of the MiniMed 780G system (MM780G) can result in a reduction in mean and standard deviation (SD) of sensor glucose (SG) values. We assessed the significance of the coefficient of variation (CV) as a measure of hypoglycaemia risk and glycaemic control. MATERIALS AND

METHODS:

Data from 10 404 MM780G users were analysed using multivariable logistic regression to assess the contribution of CV to (a) hypoglycaemia risk, measured as not reaching target <1% for time below range (TBR), and (b) achieving targets of time-in-range (TIR) >70% and glucose management indicator <7%. CV was compared with SD and low blood glucose index. To assess the relevance of CV <36% as a therapeutic threshold, we identified the CV cut-off point that optimally discriminated users at risk of hypoglycaemia.

RESULTS:

The contribution of CV was the smallest in terms of risk of hypoglycaemia (vs. low blood glucose index and SD) and TIR and glucose management indicator targets (vs. SD). In all cases the models with SD showed the best fit. A CV <43.4% (95% CI 42.9-43.9) was the optimal cut-off point with a correct classification rate of 87.2% (vs. 72.9% for CV <36%).

CONCLUSION:

For MM780G users, CV is a poor marker for hypoglycaemia risk and glycaemic control. We recommend using, for the former, TBR and whether the TBR target is met (and not using CV <36% as a therapeutic threshold for hypoglycaemia); for the latter, TIR, time above range, whether targets are met and a discrete description of mean SG and SD of SG values.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Diabetes Mellitus Tipo 1 / Insulinas / Hipoglucemia Tipo de estudio: Etiology_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Diabetes Obes Metab Asunto de la revista: ENDOCRINOLOGIA / METABOLISMO Año: 2023 Tipo del documento: Article País de afiliación: Países Bajos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Diabetes Mellitus Tipo 1 / Insulinas / Hipoglucemia Tipo de estudio: Etiology_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: Diabetes Obes Metab Asunto de la revista: ENDOCRINOLOGIA / METABOLISMO Año: 2023 Tipo del documento: Article País de afiliación: Países Bajos