A Reliable Production System of Large Quantities of [13N]Ammonia for Multiple Human Injections.
Alonso Martinez, Luis Michel; Naim, Nabil; Saiz, Alejandro Hernandez; Simard, José-Mathieu; Boudjemeline, Mehdi; Juneau, Daniel; DaSilva, Jean N.
Afiliación
  • Alonso Martinez LM; Radiochemistry and Cyclotron Platform, Centre de Recherche du Centre Hospitalier de l'Université de Montréal (CRCHUM), 900 Rue Saint Denis, Montréal, QC H2X 0A9, Canada.
  • Naim N; Radiochemistry and Cyclotron Platform, Centre de Recherche du Centre Hospitalier de l'Université de Montréal (CRCHUM), 900 Rue Saint Denis, Montréal, QC H2X 0A9, Canada.
  • Saiz AH; Radiochemistry and Cyclotron Platform, Centre de Recherche du Centre Hospitalier de l'Université de Montréal (CRCHUM), 900 Rue Saint Denis, Montréal, QC H2X 0A9, Canada.
  • Simard JM; Radiochemistry and Cyclotron Platform, Centre de Recherche du Centre Hospitalier de l'Université de Montréal (CRCHUM), 900 Rue Saint Denis, Montréal, QC H2X 0A9, Canada.
  • Boudjemeline M; Radiopharmaceutical Science Laboratory, CHU de Québec, 2250 Boul. Henri-Bourassa, Québec, QC G1J 5B3, Canada.
  • Juneau D; Radiochemistry and Cyclotron Platform, Centre de Recherche du Centre Hospitalier de l'Université de Montréal (CRCHUM), 900 Rue Saint Denis, Montréal, QC H2X 0A9, Canada.
  • DaSilva JN; Radiopharmaceutical Science Laboratory, CHU de Québec, 2250 Boul. Henri-Bourassa, Québec, QC G1J 5B3, Canada.
Molecules ; 28(11)2023 Jun 02.
Article en En | MEDLINE | ID: mdl-37298995
ABSTRACT
[13N]Ammonia is one of the most commonly used Positron Emission Tomography (PET) radiotracers in humans to assess myocardial perfusion and measure myocardial blood flow. Here, we report a reliable semi-automated process to manufacture large quantities of [13N]ammonia in high purity by proton-irradiation of a 10 mM aqueous ethanol solution using an in-target process under aseptic conditions. Our simplified production system is based on two syringe driver units and an in-line anion-exchange purification for up to three consecutive productions of ~30 GBq (~800 mCi) (radiochemical yield = 69 ± 3% n.d.c) per day. The total manufacturing time, including purification, sterile filtration, reformulation, and quality control (QC) analyses performed before batch release, is approximately 11 min from the End of Bombardment (EOB). The drug product complies with FDA/USP specifications and is supplied in a multidose vial allowing for two doses per patient, two patients per batch (4 doses/batch) on two separate PET scanners simultaneously. After four years of use, this production system has proved to be easy to operate and maintain at low costs. Over the last four years, more than 1000 patients have been imaged using this simplified procedure, demonstrating its reliability for the routine production of large quantities of current Good Manufacturing Practices (cGMP)-compliant [13N]ammonia for human use.