Your browser doesn't support javascript.
loading
Accuracy Improvement of a Compact 85Rb Atom Gravimeter by Suppressing Laser Crosstalk and Light Shift.
Ge, Guiguo; Chen, Xi; Li, Jinting; Zhang, Danfang; He, Meng; Wang, Wenzhang; Zhou, Yang; Zhong, Jiaqi; Tang, Biao; Fang, Jie; Wang, Jin; Zhan, Mingsheng.
Afiliación
  • Ge G; Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences, Wuhan 430071, China.
  • Chen X; University of Chinese Academy of Sciences, Beijing 100049, China.
  • Li J; Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences, Wuhan 430071, China.
  • Zhang D; Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences, Wuhan 430071, China.
  • He M; University of Chinese Academy of Sciences, Beijing 100049, China.
  • Wang W; Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences, Wuhan 430071, China.
  • Zhou Y; University of Chinese Academy of Sciences, Beijing 100049, China.
  • Zhong J; Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences, Wuhan 430071, China.
  • Tang B; University of Chinese Academy of Sciences, Beijing 100049, China.
  • Fang J; Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences, Wuhan 430071, China.
  • Wang J; University of Chinese Academy of Sciences, Beijing 100049, China.
  • Zhan M; Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences, Wuhan 430071, China.
Sensors (Basel) ; 23(13)2023 Jul 03.
Article en En | MEDLINE | ID: mdl-37447964
ABSTRACT
We design and implement a compact 85Rb atom gravimeter (AG). The diameter of the sensor head is 35 cm and the height is 65 cm; the optical and electronic systems are installed in four standard 3U cabinets. The measurement accuracy of this AG is improved by suppress laser crosstalk and light shift. In addition, the angle of the Raman laser reflector is adjusted and locked, and the attitude of the sensing head is automatically adjusted, and the vibration noise is also compensated. The comparison measurement results between this AG and the superconducting gravimeter indicate that its long-term stability is 0.65 µGal @50000 s.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Fenómenos Fisiológicos Celulares / Electrónica Idioma: En Revista: Sensors (Basel) Año: 2023 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Fenómenos Fisiológicos Celulares / Electrónica Idioma: En Revista: Sensors (Basel) Año: 2023 Tipo del documento: Article País de afiliación: China