Your browser doesn't support javascript.
loading
A Novel Method for Monitoring N-Nitrosamines Impurities Using NH2-MIL-101(Fe) Mediated Dispersive Micro-Solid Phase Extraction Coupled with LC-MS/MS in Biopharmaceuticals.
Xie, Yangguo; Zhang, Lei; Hou, Wei; Cheng, Ying; Luo, Feifei; Liu, Zhuoyu; Zhang, Zhongli.
Afiliación
  • Xie Y; Analytical Science and Development, Henlius Biologics Co., Ltd, 5155 Guangfulin Road, Shanghai 201616, China.
  • Zhang L; Analytical Science and Development, Henlius Biologics Co., Ltd, 5155 Guangfulin Road, Shanghai 201616, China. Electronic address: Lei_Zhang@henlius.com.
  • Hou W; Analytical Science and Development, Henlius Biologics Co., Ltd, 5155 Guangfulin Road, Shanghai 201616, China.
  • Cheng Y; Analytical Science and Development, Henlius Biologics Co., Ltd, 5155 Guangfulin Road, Shanghai 201616, China.
  • Luo F; Analytical Science and Development, Henlius Biologics Co., Ltd, 5155 Guangfulin Road, Shanghai 201616, China.
  • Liu Z; Analytical Science and Development, Henlius Biologics Co., Ltd, 5155 Guangfulin Road, Shanghai 201616, China.
  • Zhang Z; Analytical Science and Development, Henlius Biologics Co., Ltd, 5155 Guangfulin Road, Shanghai 201616, China. Electronic address: Zhongli_Zhang@henlius.com.
J Pharm Sci ; 112(11): 2783-2789, 2023 Nov.
Article en En | MEDLINE | ID: mdl-37481163
ABSTRACT
A highly efficient and convenient method for the simultaneous determination of 12 N-nitrosamines (NAs) has been developed using an amine-functionalized metal-organic framework (NH2-MIL-101(Fe)) as sorbent for dispersive micro-solid phase extraction (D-µSPE) coupled with LC-MS/MS in biopharmaceuticals. The experimental variables involved in the extraction process (i.e., amount of the sorbent, extraction time, desorption time, ionic strength, desorption solvent and volume) were optimized to achieve the best extraction efficiency of the target analytes. Under the optimum conditions, the method was successfully validated, showing good linearity in the range of 0.5-3.0 µg/L with determination coefficients (R2) higher than 0.990, repeatability (RSD ≤ 10.0%, spiked level at 2.0 µg/L) and precision (RSD ≤ 8.2%). The limit of detection (LOD) and limit of quantitation (LOQ) were in the range of 0.005-0.025 µg/L and 0.010-0.250 µg/L, respectively. Satisfactory recoveries ranging from 82.4 to 116.8% were obtained by spiking standards at three different concentrations (0.5 µg/L, 2.0 µg/L and 3.0 µg/L). Other validation parameters, including specificity, stability, and robustness, met the validation criteria. More importantly, the plausible adsorption mechanism on NH2-MIL-101(Fe) was proposed by Fourier-transform infrared (FTIR) spectra technique. Finally, this method was successfully applied to detect trace nitrosamines in biopharmaceuticals.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: J Pharm Sci Año: 2023 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: J Pharm Sci Año: 2023 Tipo del documento: Article País de afiliación: China