Radiomics in the characterization of lipid-poor adrenal adenomas at unenhanced CT: time to look beyond usual density metrics.
Eur Radiol
; 34(1): 422-432, 2024 Jan.
Article
en En
| MEDLINE
| ID: mdl-37566266
OBJECTIVES: In this study, we developed a radiomic signature for the classification of benign lipid-poor adenomas, which may potentially help clinicians limit the number of unnecessary investigations in clinical practice. Indeterminate adrenal lesions of benign and malignant nature may exhibit different values of key radiomics features. METHODS: Patients who had available histopathology reports and a non-contrast-enhanced CT scan were included in the study. Radiomics feature extraction was done after the adrenal lesions were contoured. The primary feature selection and prediction performance scores were calculated using the least absolute shrinkage and selection operator (LASSO). To eliminate redundancy, the best-performing features were further examined using the Pearson correlation coefficient, and new predictive models were created. RESULTS: This investigation covered 50 lesions in 48 patients. After LASSO-based radiomics feature selection, the test dataset's 30 iterations of logistic regression models produced an average performance of 0.72. The model with the best performance, made up of 13 radiomics features, had an AUC of 0.99 in the training phase and 1.00 in the test phase. The number of features was lowered to 5 after performing Pearson's correlation to prevent overfitting. The final radiomic signature trained a number of machine learning classifiers, with an average AUC of 0.93. CONCLUSIONS: Including more radiomics features in the identification of adenomas may improve the accuracy of NECT and reduce the need for additional imaging procedures and clinical workup, according to this and other recent radiomics studies that have clear points of contact with current clinical practice. CLINICAL RELEVANCE STATEMENT: The study developed a radiomic signature using unenhanced CT scans for classifying lipid-poor adenomas, potentially reducing unnecessary investigations that scored a final accuracy of 93%. KEY POINTS: ⢠Radiomics has potential for differentiating lipid-poor adenomas and avoiding unnecessary further investigations. ⢠Quadratic mean, strength, maximum 3D diameter, volume density, and area density are promising predictors for adenomas. ⢠Radiomics models reach high performance with average AUC of 0.95 in the training phase and 0.72 in the test phase.
Palabras clave
Texto completo:
1
Colección:
01-internacional
Banco de datos:
MEDLINE
Asunto principal:
Adenoma Corticosuprarrenal
/
Radiómica
Tipo de estudio:
Prognostic_studies
Límite:
Humans
Idioma:
En
Revista:
Eur Radiol
Asunto de la revista:
RADIOLOGIA
Año:
2024
Tipo del documento:
Article
País de afiliación:
Italia