Your browser doesn't support javascript.
loading
Highly sensitive digital detection of SARS-CoV-2 nucleocapsid protein through single-molecule counting.
Dou, Xuechen; Zhang, Zhiwei; Liu, Bo; Li, Chao; Du, Yaohua; Tian, Feng.
Afiliación
  • Dou X; Medical Support Technology Research Department, Systems Engineering Institute, Academy of Military Sciences, People's Liberation Army, Tianjin, 30161, China.
  • Zhang Z; Medical Support Technology Research Department, Systems Engineering Institute, Academy of Military Sciences, People's Liberation Army, Tianjin, 30161, China.
  • Liu B; Medical Support Technology Research Department, Systems Engineering Institute, Academy of Military Sciences, People's Liberation Army, Tianjin, 30161, China.
  • Li C; Medical Support Technology Research Department, Systems Engineering Institute, Academy of Military Sciences, People's Liberation Army, Tianjin, 30161, China.
  • Du Y; National Bio-Protection Engineering Center, Tianjin, 300161, China.
  • Tian F; Medical Support Technology Research Department, Systems Engineering Institute, Academy of Military Sciences, People's Liberation Army, Tianjin, 30161, China. qsyaohua@hotmail.com.
Anal Bioanal Chem ; 415(25): 6155-6164, 2023 Oct.
Article en En | MEDLINE | ID: mdl-37596347
ABSTRACT
Nucleocapsid protein (NP) is one of the structural proteins of SARS-CoV-2 which is stable, well-conserved, highly immunogenic, and abundantly expressed due to the host's adaptive immune response, making it a promising antigenic biomarker for the early and rapid identification and diagnosis of SARS-CoV-2. Traditional antigen analytical methods with NP as the detection marker often have insufficient sensitivity. To achieve rapid and highly sensitive detection of NP, we constructed a novel single-molecule (digital) fluorescence-linked immunosorbent assay (FLISA) based on streptavidin-modified transparent 96-well microplates. Streptavidin was immobilized on the microplate under optimized conditions with a 15 mM carbonate buffer solution (pH 9.6) as the coating solution, biotinylated antibodies conjugated with streptavidin as capture probes, and carboxylated fluorescent microsphere-conjugated monoclonal antibodies (FMs-mAbs) as fluorescent probes. Individual sandwich immunolabeled complexes of the SARS-CoV-2 diagnostic marker NP were detected and counted though wide-field inverted fluorescence microscopy (1.1 × 1.4 mm2). FLISA had a linear detection range of 0.2 pg/mL to 200 ng/mL and a limit of detection (LOD) of 0.73 fg/mL and 8 fg/mL for NP in phosphate buffer saline and spiked nasal swab samples, respectively. The sensitivity was much higher than commercial antigen detection kits, providing wide detection prospects in future clinical diagnosis, environmental monitoring, and other fields.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Anal Bioanal Chem Año: 2023 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Anal Bioanal Chem Año: 2023 Tipo del documento: Article País de afiliación: China