Your browser doesn't support javascript.
loading
Simultaneous Quantification of Biomarkers for Bis-(2-chloroethyl) Sulfide and 1,2-Bis(2-chloroethylthio) Ethane Exposure in Human Urine at Trace Exposure Levels by Gas Chromatography Tandem Mass Spectrometry via Simultaneous Incubation and Extraction.
Li, Xiao-Sen; Yang, Fang-Chao; Yan, Long; Wu, Ji-Na; Yuan, Ling; Yang, Yang; Liu, Shi-Lei.
Afiliación
  • Li XS; State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China.
  • Yang FC; School of Chemistry and Chemical Engineering, Nanjing University of Sciences & Technology, Nanjing 210094, P. R. China.
  • Yan L; State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China.
  • Wu JN; State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China.
  • Yuan L; State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China.
  • Yang Y; State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China.
  • Liu SL; State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China.
Chem Res Toxicol ; 36(9): 1549-1559, 2023 09 18.
Article en En | MEDLINE | ID: mdl-37657424
ABSTRACT
Sulfur mustard [HD; bis-(2-chloroethyl) sulfide] and other analogues are a kind of highly toxic vesicant and have been prohibited by the Organization for the Prohibition of Chemical Weapons (OPCW) since 1997. Exposures to HD could generate several adducts in the plasma and hydrolysis products in the urine, which are widely applied as biomarkers to identify HD exposure in forensic analysis. Several methods have been developed for the detection of related biomarkers. However, most methods are based on complex derivatization, and not enough attention is paid to HD analogues. A modified and convenient analytical method reported herein includes simultaneous incubation and organic solvent extraction. The biomarkers such as thiodiglycol and 1,2-bis (2-hydroxyethylthio) are transferred to HD and 1,2-bis(2-chloroethylthio) ethane via hydrochloric acid at the appropriate temperature. The analytes are analyzed by gas chromatography tandem mass spectrometry (GC-MS/MS) with 2-chloroethyl ethyl sulfide (2-CEES) applied as the internal standard. The interday and intraday study according to FDA rules has been achieved to evaluate the accuracy and precision of the method. The two targets are detected with a good linearity (R2 > 0.99) in the concentration ranges from 5 to 1000 ng/mL and 10 to 1000 ng/mL, with small relative standard deviations (RSD ≤6.62% and RSD ≤6.93%) and favorable recoveries between 90.3 and 107.3% and between 89.4 and 108.7%, respectively. The established method can be used for retrospective detection of sulfur mustards in biological samples and successfully applied in the biomedical proficiency testing organized by the OPCW.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Sulfuros / Espectrometría de Masas en Tándem Tipo de estudio: Observational_studies Límite: Humans Idioma: En Revista: Chem Res Toxicol Asunto de la revista: TOXICOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Sulfuros / Espectrometría de Masas en Tándem Tipo de estudio: Observational_studies Límite: Humans Idioma: En Revista: Chem Res Toxicol Asunto de la revista: TOXICOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: China