Your browser doesn't support javascript.
loading
Reduced graphene oxide-persimmon tannin/Pt@Pd nanozyme-based cascade colorimetric sensor for detection of 1,5-anhydroglucitol.
Li, Guiyin; Li, Xinhao; Xu, Wenfeng; Li, Shennan; Tan, Xiaohong; Liang, Jintao; Zhou, Zhide.
Afiliación
  • Li G; College of Chemistry, Guangdong University of Petrochemical Technology, Guandu Road, Maoming, Guangdong, 525000, People's Republic of China. liguiyin01@gdupt.edu.cn.
  • Li X; Guangxi Key Laboratory of Information Materials, School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi, 541004, People's Republic of China. liguiyin01@gdupt.edu.cn.
  • Xu W; College of Chemistry, Guangdong University of Petrochemical Technology, Guandu Road, Maoming, Guangdong, 525000, People's Republic of China.
  • Li S; Guangxi Key Laboratory of Information Materials, School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi, 541004, People's Republic of China.
  • Tan X; Guangxi Key Laboratory of Information Materials, School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi, 541004, People's Republic of China.
  • Liang J; Guangxi Key Laboratory of Information Materials, School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi, 541004, People's Republic of China.
  • Zhou Z; College of Chemistry, Guangdong University of Petrochemical Technology, Guandu Road, Maoming, Guangdong, 525000, People's Republic of China.
Anal Bioanal Chem ; 415(29-30): 7103-7115, 2023 Dec.
Article en En | MEDLINE | ID: mdl-37837540
ABSTRACT
1,5-anhydroglucitol (1,5-AG) is of considerable clinical relevance as a biochemical marker of glucose metabolism in the assessment and monitoring of diabetes. Herein, a simple colorimetric biosensor was constructed for the identification and detection of 1,5-AG by using pyranose oxidase (PROD) enzyme cascaded with reduced graphene oxide/persimmon tannin/Pt@Pd (RGO-PT/Pt@Pd NPs) nanozyme. The as-prepared RGO-PT/Pt@Pd NPs had excellent peroxidase-like activity and can be applied as a nanozyme. First, PROD enzyme reacts with the target 1,5-AG, decomposing 1,5-AG into 1,5-anhydrofuctose (1,5-AF) and H2O2. At this point, the highly catalytic RGO-PT/Pt@Pd NPs nanozyme produces a cascade with PROD enzyme which catalyzes the decomposition of H2O2 to produce O2. This in turn oxidizes the substrate 3,3',5,5'-tetramethylbenzidine (TMB) and produces a color change in the solution. Finally, the detection of 1,5-AG was achieved by measuring the absorption peak at 652 nm with an ultraviolet visible (UV-vis) spectrophotometer. Under optimal conditions, the linear operating range of the 1,5-AG enzyme cascade colorimetric sensor was 1.0-100.0 µg/mL, and the limit of detection (LOD) was 0.81 µg/mL. The proposed colorimetric biosensor was successfully applied to detect 1,5-AG in spiked human serum samples with the recoveries of 97.2-103.9% and RSDs of 1.94-4.48%. It provides a promising developmental assay for clinical detection of 1,5-AG.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Diospyros / Peróxido de Hidrógeno Límite: Humans Idioma: En Revista: Anal Bioanal Chem Año: 2023 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Diospyros / Peróxido de Hidrógeno Límite: Humans Idioma: En Revista: Anal Bioanal Chem Año: 2023 Tipo del documento: Article