The corneal biomechanical differences after wearing orthokeratology lenses and multifocal soft lenses in children: A self-control study.
Fu, Lin; Jiang, Yi; Lian, Hengli; Lou, Jiangtao; Chen, Ruru; Li, Zhangliang; Zhang, Yunjie.
Afiliación
  • Fu L; National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, China. Electronic address: 18357115864@eye.ac.cn.
  • Jiang Y; National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, China. Electronic address: 1663044070@qq.com.
  • Lian H; National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, China. Electronic address: lhl526@mail.eye.ac.cn.
  • Lou J; National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, China. Electronic address: loujiangtao@eye.ac.cn.
  • Chen R; National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, China. Electronic address: 13868051650@eye.ac.cn.
  • Li Z; National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, China. Electronic address: 13968832833@eye.ac.cn.
  • Zhang Y; National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, China. Electronic address: 13750828781@eye.ac.cn.
Cont Lens Anterior Eye ; 47(1): 102089, 2024 Feb.
Article en En | MEDLINE | ID: mdl-37951739
ABSTRACT

BACKGROUND:

To compare the changes in corneal biomechanics after orthokeratology (OK) lens and Defocus Incorporated Soft Contact (DISC) lens treatment.

METHODS:

Of 28 myopic children were recruited, with one eye wearing OK lens and the other eye wearing DISC lens for one year, and the data after discontinued for 4 weeks were also collected. Major outcomes were corneal biomechanics and axial length (AL) elongation.

RESULTS:

Throughout the follow-up period, the DISC group had longer the first applanation (A1) time, larger A1 deformation amplitude, A1 deflection length (A1 DLL), and A1 deflection amplitude than the OK group. AL elongation was less in the OK group at each visit (all P < 0.05) but faster in the OK group than in the DISC group after discontinuation (P = 0.006). Moreover, AL elongation was related to baseline A1 time, A1 velocity and whole eye movement max in the DISC group, and in the OK group, was related to the baseline the second applanation (A2) DLL, A2 delta arc length and stiffness parameter A1 (all P < 0.05).

CONCLUSIONS:

The cornea was more deformable after wearing DISC lens than OK lens, and corneal biomechanical parameters were associated with AL elongation. Eyes showed less AL elongation during OK lens treatment while faster AL elongation after discontinuation than DISC lens. The baseline corneal biomechanics may help to predict AL elongation in myopic control strategies.