Your browser doesn't support javascript.
loading
Challenges and Pragmatic Solutions for Assessing the Reliability of HIV-1 Viral Load Monitoring in Resource-Constrained Settings.
Demosthenes, John Paul; Ghale, Ben Chirag; Alex, Diviya; Ramalingam, Veena Vadhini; Fletcher, Gnanadurai John; Abraham, Priya; Kannangai, Rajesh.
Afiliación
  • Demosthenes JP; Department of Clinical Virology, Christian Medical College, Vellore, India, johndemo@cmcvellore.ac.in.
  • Ghale BC; Department of Clinical Virology, Christian Medical College, Vellore, India.
  • Alex D; Department of Clinical Virology, Christian Medical College, Vellore, India.
  • Ramalingam VV; Department of Clinical Virology, Christian Medical College, Vellore, India.
  • Fletcher GJ; Department of Clinical Virology, Christian Medical College, Vellore, India.
  • Abraham P; Department of Clinical Virology, Christian Medical College, Vellore, India.
  • Kannangai R; Department of Clinical Virology, Christian Medical College, Vellore, India.
Intervirology ; 67(1): 1-5, 2024.
Article en En | MEDLINE | ID: mdl-38008075
INTRODUCTION: HIV-1 RNA detection is the most reliable method for monitoring treatment response among people living with HIV. Effective quality control measures that include internal quality control (IQC) are challenging in resource-constrained settings. METHODS: We ascertained the utility of the kit low positive control (LPC) as an effective IQC to monitor the reliability of the HIV-1 viral load assay. Variations in LPC values were measured for 390 different runs over 10 years (2011-2021) and compared to in-house IQC data using Levey-Jennings control chart. RESULTS: Overall, the Levey-Jennings analysis showed minimal variation (±0.5 log) for both the LPC and IQC data. The mean LPC value for first 20 runs (20 days) was 2.91. The mean LPC value for the 390 runs comprising 35 different lots was 3.01 ± 0.1 log. CONCLUSION: Our decadal data reveal that Abbott RealTime HIV-1 assay (Abbott Molecular Inc., IL, USA) LPC exhibited no significant biological variation over 390 runs distributed over 10 years. Hence, assay LPC can supplant the IQC for monitoring assay trends as a stable and commutable material in resource-constrained settings.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Infecciones por VIH / VIH-1 Límite: Humans Idioma: En Revista: Intervirology Año: 2024 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Infecciones por VIH / VIH-1 Límite: Humans Idioma: En Revista: Intervirology Año: 2024 Tipo del documento: Article