Your browser doesn't support javascript.
loading
Encouraging Regular Aortic Valve Opening for EVAHEART 2 LVAD Support Using Virtual Patient Hemodynamic Speed Modulation Analysis.
Martinez, Jasmine; Smegner, Kelsey; Tomoda, Masae; Motomura, Tadashi; Chivukula, Venkat Keshav.
Afiliación
  • Martinez J; From the Department of Biomedical Engineering and Science, Florida Institute of Technology, Melbourne, Florida.
  • Smegner K; Evaheart Inc., Houston, Texas.
  • Tomoda M; Evaheart Inc., Houston, Texas.
  • Motomura T; Evaheart Inc., Houston, Texas.
  • Chivukula VK; From the Department of Biomedical Engineering and Science, Florida Institute of Technology, Melbourne, Florida.
ASAIO J ; 70(3): 207-216, 2024 Mar 01.
Article en En | MEDLINE | ID: mdl-38029749
This study focuses on investigating the EVAHEART 2 left ventricular assist device (LVAD) toward designing optimal pump speed modulation (PSM) algorithms for encouraging aortic valve (AV) flow. A custom-designed virtual patient hemodynamic model incorporating the EVAHEART 2 pressure-flow curves, cardiac chambers, and the systemic and pulmonary circulations was developed and used in this study. Several PSM waveforms were tested to evaluate their influence on the mean arterial pressure (MAP), cardiac output (CO), and AV flow for representative heart failure patients. Baseline speeds were varied from 1,600 to 2,000 rpm. For each baseline speed, the following parameters were analyzed: 1) PSM ratio (reduced speed/baseline speed), 2) PSM duration (3-7 seconds), 3) native ventricle contractility, and 4) patient MAP of 70 and 80 mm Hg. More than 2,000 rpm virtual patient scenarios were explored. A lower baseline speed (1,600 and 1,700 rpm) produced more opportunities for AV opening and more AV flow. Higher baseline speeds (1,800 and 2,000 rpm) had lower or nonexistent AV flow. When analyzing PSM ratios, a larger reduction in speed (25%) over a longer PSM (5+ seconds) duration produced the most AV flow. Lower patient MAP and increased native ventricle contractility also contributed to improving AV opening frequency and flow. This study of the EVAHEART 2 LVAD is the first to focus on leveraging PSM to enhance pulsatility and encourage AV flow. Increased AV opening frequency can benefit aortic root hemodynamics, thereby improving patient outcomes.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Corazón Auxiliar / Insuficiencia Cardíaca Límite: Humans Idioma: En Revista: ASAIO J Asunto de la revista: TRANSPLANTE Año: 2024 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Corazón Auxiliar / Insuficiencia Cardíaca Límite: Humans Idioma: En Revista: ASAIO J Asunto de la revista: TRANSPLANTE Año: 2024 Tipo del documento: Article