Your browser doesn't support javascript.
loading
Development and validation of a UPLC-PDA method for quantifying ceftazidime in dried blood spots.
Lv, Jianmei; Wu, Qiping; Li, Sanwang; Yi, Hanxi; Xie, Feifan.
Afiliación
  • Lv J; Division of Biopharmaceutics and Pharmacokinetics, Xiangya School of Pharmaceutical Sciences, Central South University, Changsha 410013, China.
  • Wu Q; Division of Biopharmaceutics and Pharmacokinetics, Xiangya School of Pharmaceutical Sciences, Central South University, Changsha 410013, China.
  • Li S; Department of Pharmacy, The Second Xiangya Hospital, Central South University, Changsha, China; Institute of Clinical Pharmacy, Central South University, Changsha, China.
  • Yi H; Department of Pathology, School of Basic Medical Science, Central South University, Changsha, China.
  • Xie F; Division of Biopharmaceutics and Pharmacokinetics, Xiangya School of Pharmaceutical Sciences, Central South University, Changsha 410013, China. Electronic address: feifan.xie@csu.edu.cn.
J Pharm Biomed Anal ; 239: 115928, 2024 Feb 15.
Article en En | MEDLINE | ID: mdl-38134705
ABSTRACT
Bacterial infection is a leading cause of neonatal death. Ceftazidime, commonly used for neonatal infections, is often used off-label. Blood sampling limits pharmacokinetic (PK) studies in neonatal patients. The dried blood spots (DBS) are a potential matrix for microsampling. Herein, we describe an ultra-performance liquid chromatography with a photodiode array (UPLC-PDA) to determine ceftazidime in DBS from neonatal patients in support of pharmacokinetic studies. The Capitainer® device-based DBS samples containing 10 µL blood were extracted in 70% methanol/water (v/v) with acetaminophen as the internal standard (IS). The extraction process was carried out at 20 °C using a block bath shaker at 1000 rpm for 30 min. The extracted ceftazidime was subsequently eluted through an Acquity UPLC HSS T3 column (2.1 × 50 mm, 1.8 µm). Elution was achieved using a water (containing 0.1% trifluoroacetic acid)/acetonitrile linear gradient at a flow rate of 0.5 mL/min, and the analytical time was 3.2 min. The PDA detection wavelength was set at 259 nm. The method underwent thorough validation following the recommendation of the European Bioanalysis Forum (EBF) and the bioanalytical guideline established by the European Medicines Agency (EMA). No interfering peaks were detected at the retention times of ceftazidime and IS. The ceftazidime exhibited a quantification range spanning from 0.5 to 200 µg/mL, and the assay demonstrated good accuracy (intra/inter-assay ranging from 90.1% to 104.8%) and precision (intra/inter-assay coefficient of variations ranging from 4.8% to 11.7%). The method's applicability was demonstrated by analyzing clinical DBS samples collected from neonatal patients.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Agua / Ceftazidima Límite: Humans / Newborn Idioma: En Revista: J Pharm Biomed Anal Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Agua / Ceftazidima Límite: Humans / Newborn Idioma: En Revista: J Pharm Biomed Anal Año: 2024 Tipo del documento: Article País de afiliación: China