Your browser doesn't support javascript.
loading
The Influence of the Nature of the Polymer Incorporating the Same A3B Multifunctional Porphyrin on the Optical or Electrical Capacity to Recognize Procaine.
Lascu, Anca; Vlascici, Dana; Birdeanu, Mihaela; Epuran, Camelia; Fratilescu, Ion; Fagadar-Cosma, Eugenia.
Afiliación
  • Lascu A; Institute of Chemistry "Coriolan Dragulescu", Mihai Viteazu Ave. 24, 300223 Timisoara, Romania.
  • Vlascici D; Faculty of Chemistry, Biology, Geography, West University of Timisoara, 4 Vasile Parvan Ave., 300223 Timisoara, Romania.
  • Birdeanu M; National Institute for Research and Development in Electrochemistry and Condensed Matter, Plautius Andronescu Street 1, 300224 Timisoara, Romania.
  • Epuran C; Institute of Chemistry "Coriolan Dragulescu", Mihai Viteazu Ave. 24, 300223 Timisoara, Romania.
  • Fratilescu I; Institute of Chemistry "Coriolan Dragulescu", Mihai Viteazu Ave. 24, 300223 Timisoara, Romania.
  • Fagadar-Cosma E; Institute of Chemistry "Coriolan Dragulescu", Mihai Viteazu Ave. 24, 300223 Timisoara, Romania.
Int J Mol Sci ; 24(24)2023 Dec 08.
Article en En | MEDLINE | ID: mdl-38139093
ABSTRACT
The multifunctionality of an A3B mixed-substituted porphyrin, namely 5-(4-carboxyphenyl)-10,15,20-tris(4-methylphenyl)porphyrin (5-COOH-3MPP), was proven due to its capacity to detect procaine by different methods, depending on the polymer matrix in which it is incorporated. The hybrid nanomaterial containing k-carrageenan and AuNPs (5-COOH-3MPP-k-carrageenan-AuNPs) was able to optically detect procaine in the concentration range from 5.76 × 10-6 M to 2.75 × 10-7 M, with a limit of detection (LOD) of 1.33 × 10-7 M. This method for the detection of procaine gave complementary results to the potentiometric one, which uses 5-COOH-3MPP as an electroactive material incorporated in a polyvinylchloride (PVC) membrane plasticized with o-NPOE. The detected concentration range by this ion-selective membrane electrode is wider (enlarged in the field of higher concentrations from 10-2 to 10-6 M), linearly dependent with a 53.88 mV/decade slope, possesses a detection limit of 7 × 10-7 M, a response time of 60 s, and has a certified stability for a working period of six weeks.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Porfirinas / Nanopartículas del Metal Idioma: En Revista: Int J Mol Sci Año: 2023 Tipo del documento: Article País de afiliación: Rumanía

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Porfirinas / Nanopartículas del Metal Idioma: En Revista: Int J Mol Sci Año: 2023 Tipo del documento: Article País de afiliación: Rumanía