Nucleic acid aptasensor with magnetically induced self-assembly for the detection of EpCAM glycoprotein.
Yue, Yao; Ouyang, Hezhong; Ma, Mingyi; Yang, Yaping; Zhang, Haoda; He, Aolin; Liu, Ruijiang.
Afiliación
  • Yue Y; School of Pharmacy, Jiangsu University, Zhenjiang, 212013, People's Republic of China.
  • Ouyang H; The People's Hospital of Danyang, Affiliated Danyang Hospital of Nantong University, Zhenjiang, 212300, People's Republic of China.
  • Ma M; School of Pharmacy, Jiangsu University, Zhenjiang, 212013, People's Republic of China.
  • Yang Y; School of Pharmacy, Jiangsu University, Zhenjiang, 212013, People's Republic of China.
  • Zhang H; School of Pharmacy, Jiangsu University, Zhenjiang, 212013, People's Republic of China.
  • He A; Affiliated Kunshan Hospital, Jiangsu University, Suzhou, 215300, People's Republic of China. aolinhe@163.com.
  • Liu R; School of Pharmacy, Jiangsu University, Zhenjiang, 212013, People's Republic of China. luckystar_lrj@ujs.edu.cn.
Mikrochim Acta ; 191(1): 64, 2023 12 29.
Article en En | MEDLINE | ID: mdl-38157059
ABSTRACT
A "turn-on" aptasensor for label-free and cell-free EpCAM detection was constructed by employing magnetic α-Fe2O3/Fe3O4@Au nanocomposites as a matrix for signal amplification and double-stranded complex (SH-DNA/Apt probes) immobilization through Au-S binding. α-Fe2O3/Fe3O4@Au could be efficiently assembled into uniform and stable self-assembly films via magnetic-induced self-assembly technique on a magnetic glassy carbon electrode (MGCE). The effectiveness of the platform for EpCAM detection was confirmed through differential pulse voltammetry (DPV). Under optimized conditions, the platform exhibited excellent specificity for EpCAM, and a strong linear correlation was observed between the current and the logarithm of EpCAM protein concentration in the range 1 pg/mL-1000 pg/mL (R2 = 0.9964), with a limit of detection (LOD) of 0.27 pg/mL. Furthermore, the developed platform demonstrated good stability during a 14-day storage test, with fluctuations remaining below 93.33% of the initial current value. Promising results were obtained when detecting EpCAM in spiked serum samples, suggesting its potential as a point-of-care (POC) testing.